,for, Item ID-
- #914996
- Phoenix Diagnostics #PH5001
Calibration Verification Set Blood Gas / ISE 5 X 3 X 2 mL For Blood Gas and Ion Selective Electrode Instruments
CONTROL, BG/ISE LINEARITY 5X5X2ML
Features
- Phoenix Diagnostic’s Blood Gas / Electrolyte Linearity Test Set is intended to monitor the performance of blood gas and ionselective electrode instruments in measuring pH, PCO2, PO2, Na+, K+, Cl-, ionized calcium, magnesium, glucose, lactate, BUN, and creatinine
- Phoenix Diagnostic’s Blood Gas / ISE Linearity Test Sets are sealed in ampules containing buffers and salts in bovine serum matrix, and are equilibrated with known levels of carbon dioxide, oxygen, and nitrogen
- Each test set prepared is formulated into 5 distinct levels, with 3 ampules per level, and 2mL per ampule
- More …
Product Details Email
Product Specifications
| McKesson # | 914996 |
|---|---|
| Manufacturer # | PH5001 |
| Manufacturer | Phoenix Diagnostics |
| Country of Origin | Unknown |
| Application | Calibration Verification Set |
| Buy American Act (BAA) Compliant | No |
| Container Type | Ampule |
| For Use With | For Blood Gas and Ion Selective Electrode Instruments |
| Form | Ready-to-Use Liquid |
| Levels | Level 1, 2, 3, 4, 5 |
| Test Name | Blood Gas / ISE |
| Test Type | Multi-Analyte |
| Trade Agreement Act (TAA) Compliant | No |
| UNSPSC Code | 41116107 |
| Volume | 5 X 3 X 2 mL |
Features
- Phoenix Diagnostic’s Blood Gas / Electrolyte Linearity Test Set is intended to monitor the performance of blood gas and ionselective electrode instruments in measuring pH, PCO2, PO2, Na+, K+, Cl-, ionized calcium, magnesium, glucose, lactate, BUN, and creatinine
- Phoenix Diagnostic’s Blood Gas / ISE Linearity Test Sets are sealed in ampules containing buffers and salts in bovine serum matrix, and are equilibrated with known levels of carbon dioxide, oxygen, and nitrogen
- Each test set prepared is formulated into 5 distinct levels, with 3 ampules per level, and 2mL per ampule
- Complementary ampule snapper provided with test set
Frequently Viewed Together
-
,for, Item ID-
- #769351
- Siemens #10444878
-
,for, Item ID-
- #1029975
- Siemens #10716280
-
,for, Item ID-
- #769221
- Siemens #10444997
-
,for, Item ID-
- #769209
- Siemens #10445013
-
,for, Item ID-
- #939649
- Roche Diagnostics #5213509001
-
,for, Item ID-
- #1034210
- Siemens #10711580
-
,for, Item ID-
- #1034072
- Siemens #10484354
-
,for, Item ID-
- #810463
- Abbott Point of Care #05P7001
-
,for, Item ID-
- #681990
- Sysmex America #199-5002-0
-
,for, Item ID-
- #1133282
- Beckman Coulter #B36880
-
,for, Item ID-
- #988028
- Siemens #10445005
-
,for, Item ID-
- #492053
- Abbott #8013904
-
,for, Item ID-
- #387970
- Tosoh Bioscience #0018767
-
,for, Item ID-
- #206133
- Alfa Wassermann #E1-2
-
,for, Item ID-
- #1260702
- Horiba #5300100300