-
,for, Item ID-
- #1296110
- Immunostics #SMFP-5
Immunoassay Reagent AFIAS™ Follicle Stimulating Hormone (FSH) CLIA Non-Waived For AFIAS-1, AFIAS-3, AFIAS-6, AFIAS-10 Immunoassay Analyzers 24 Tests
REAGENT, FLUORESCENCE IMNASY F/FSH (24TST/BX)
No Image
Features
- Rapid quantitative FSH measurement at the point of care in 12 minutes from whole blood, serum, or plasma - no laboratory send-out required
- Use across physician offices, fertility clinics, and urgent care settings without specialized training
- Broad clinical utility across the full FSH testing spectrum: supports diagnosis of premature ovarian failure, poor ovarian reserve, Turner syndrome, gonadal dysgenesis, and testicular failure, as well as menopausal transition monitoring
- More …
Product Details Email
Product Specifications
| McKesson # | 1296110 |
|---|---|
| Manufacturer # | SMFP-5 |
| Brand or Series | AFIAS™ |
| Manufacturer Name | Immunostics |
| Application | Immunoassay Reagent |
| Buy American Act (BAA) Compliant | No |
| CLIA Classification | CLIA Non-Waived |
| CLIA Classified | CLIA Non-Waived |
| For Use With | For AFIAS-1, AFIAS-3, AFIAS-6, AFIAS-10 Immunoassay Analyzers |
| Manufacturer Number | SMFP-5 |
| Number of Tests | 24 Tests |
| Product Dating | McKesson Acceptable Dating: we will ship >= 90 days |
| Sample Type | Whole Blood / Serum / Plasma Sample |
| Specialty | Immunoassay |
| Test Category | Reproductive Health |
| Test Format | Cartridge |
| Test Method | Fluorescence |
| Test Name | Follicle Stimulating Hormone (FSH) |
| Time to Results | 12 Minute Results |
| Trade Agreement Act (TAA) Compliant | No |
| UNSPSC Code | 41116004 |
Features
- Rapid quantitative FSH measurement at the point of care in 12 minutes from whole blood, serum, or plasma - no laboratory send-out required
- Use across physician offices, fertility clinics, and urgent care settings without specialized training
- Broad clinical utility across the full FSH testing spectrum: supports diagnosis of premature ovarian failure, poor ovarian reserve, Turner syndrome, gonadal dysgenesis, and testicular failure, as well as menopausal transition monitoring
- Reference ranges validated across follicular, mid-cycle, luteal, and postmenopausal phases in females and males
- High analytical performance with working range of 1–100 mIU/mL, LoQ of 1 mIU/mL, and CV ≤ 6.3% across repeatability, within-laboratory, lot-to-lot, between-site, and between-reader studies
- Accuracy confirmed at 96.0–102.0% recovery across 3 lots; strong comparability to reference method (R=0.9924, y=0.9929x+0.1806)
More Information
Frequently Viewed Together
-
,for, Item ID-
- #1139481
- Abbott Rapid Dx North America LLC #1116974
-
,for, Item ID-
- #661184
- Beckman Coulter #33020
-
,for, Item ID-
- #479731
- Tosoh Bioscience #0025294
-
,for, Item ID-
- #661196
- Beckman Coulter #33510
-
,for, Item ID-
- #1119813
- Abbott #07P4820
-
,for, Item ID-
- #1141849
- Abbott Rapid Dx North America LLC #1116972
-
,for, Item ID-
- #479643
- Tosoh Bioscience #0025265
-
,for, Item ID-
- #479648
- Tosoh Bioscience #0025296
-
,for, Item ID-
- #369190
- Tosoh Bioscience #0020365
-
,for, Item ID-
- #1119799
- Abbott #07P4901
-
,for, Item ID-
- #1119822
- Abbott #07P4920
-
,for, Item ID-
- #1119823
- Abbott #07P9120
-
,for, Item ID-
- #1120041
- Abbott #08P3121
-
,for, Item ID-
- #854005
- Qualigen #25000042
-
,for, Item ID-
- #635592
- Ortho Clinical Diagnostics #8559825
-
,for, Item ID-
- #861844
- Abbott #07K7525