-
,for, Item ID-
- #1013021
- Soma Technology #SSA-040716-0941
Refurbished Electrocardiograph GE MAC 1200
MACHINE, EKG GE MARQUETTE MAC 1200 6CHANNEL 12LEAD
Features
- Refurbished in an ISO 13485 Certified FDA registered Facility
- This system can be configured to meet the needs of hospitals, clinics and office-based practices
- Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
- More …
Product Details Email
Product Specifications
| McKesson # | 1013021 |
|---|---|
| Manufacturer # | SSA-040716-0941 |
| Brand | GE MAC 1200 |
| Manufacturer | Soma Technology |
| Country of Origin | Unknown |
| Application | Refurbished Electrocardiograph |
| Buy American Act (BAA) Compliant | Yes |
| Specifications | 12 Leads - Simultaneously Acquisition, Type CF according to IEC Signal Input, 1000 Samples/Sec/Channel Digital Sampling Rate, Differential Signals for AC Voltage ±, 10 mV Superimposed DC Voltage (Polarization Voltage) ±600 mV Dynamic Range, 5 uV Resolution, 0.04 to 150 Hz Frequency Response, > 140 dB Common Mode Rejection, > 100 M ohms Input Impedance, < 10 uA Leakage Current, All leads, Duration 0.1 to 2.5 ms, Amplitude > 5 mV Pacemaker Detection Sensitivity, 10 to 120 V (0.32 A)/220 to 240 V (0.16 A), 49 to 65 Hz, NiCad, 18 V, 1.4 Ah, 4 hr, 3.7 X 12.6 X 14.5 Inch |
| Trade Agreement Act (TAA) Compliant | Yes |
| UNSPSC Code | 42181701 |
Features
- Refurbished in an ISO 13485 Certified FDA registered Facility
- This system can be configured to meet the needs of hospitals, clinics and office-based practices
- Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
- Comprehensive solution for EKG requirements
- Waveform LCD display
- Interpretive EKG
- Full-size paper reports
- Portable with built-in battery
- Measurements, interpretation and memory available in any combination
- Simultaneous 12-lead ECG acquisition and analysis
- Compact, lightweight design with carrying handle
- Field upgradability
- Anti drift system (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes
- Baseline adjustment: ECG presentation on averaged baseline
- Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break; each single electrode is monitored
- Copy: In the automatic 12 lead mode , after ECG, recording, copies of the ECG can be printed
- Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input
Frequently Viewed Together
-
,for, Item ID-
- #1014325
- McKesson Brand #MLBUR280-C1X
-
,for, Item ID-
- #1014323
- McKesson Brand #MLBUR280-81X
-
,for, Item ID-
- #1014319
- McKesson Brand #MLBUR150C-81X
-
,for, Item ID-
- #1014326
- McKesson Brand #MLBUR280-W1D
-
,for, Item ID-
- #1014322
- McKesson Brand #MLBUR280-81D
-
,for, Item ID-
- #1014324
- McKesson Brand #MLBUR280-C1D
-
,for, Item ID-
- #1231324
- Midmark #4-000-0080
-
,for, Item ID-
- #1254088
- GE Healthcare #8855001-001-01247423
-
,for, Item ID-
- #1030641
- EdanUSA & MDPro #SE-1200 EXPRESS BASIC
-
,for, Item ID-
- #1196779
- GE Healthcare #2110731-001
-
,for, Item ID-
- #1241841
- EdanUSA & MDPro #01.57.040172
-
,for, Item ID-
- #875985
- Welch Allyn #BUR280-81X
-
,for, Item ID-
- #1124423
- EdanUSA & MDPro #SE-301
-
,for, Item ID-
- #1020135
- Sage Services Group #900995-002