Product Comparison


  Sysmex America XN-350

No Image

Sysmex America XN-530

No Image

Sysmex America XN-330
McKesson # 1066124 861611 1163498 1066128 1066127
Description Hematology Analyzer XN-L Series CLIA Non-Waived Hematology Analyzer Cell-Dyn Emerald CLIA Non-Waived Hematology Analyzer XN-Series CLIA Non-Waived Hematology Analyzer XN-L Series CLIA Non-Waived Hematology Analyzer XN-L Series CLIA Non-Waived
Manufacturer # XN-35009H3901XN-530XN-430XN-330
Brand XN-L SeriesCell-Dyn EmeraldXN-SeriesXN-L SeriesXN-L Series
Manufacturer Sysmex AmericaAbbottSysmex AmericaSysmex AmericaSysmex America
Invoice ANALYZER, HEMATOLOGY XN-350 OPEN TUBE SAMPLE D/SANALYZER, HEMO EMRLD CELLDYN INCLUDED W/861516/923451 D/SANALYZER, SYSMEX XN-530 6-PARTDIFF W/AUTOLOADER D/SANALYZER, HEMATOLOGY XN-430 CLOSED MODE SAMPLER D/SANALYZER, HEMATOLOGY XN-330 OPEN TUBE SAMPLE D/S
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

Contents 1 XN-350 Automated Hematology AnalyzerAnalyzer, UPS, FreightXN-530 Automated Hematology AnalyzerXN-430 Automated Hematology Analyzer
Country of Origin JapanGermanyJapanJapanJapan
Dimensions 17-3/4 X 18-1/3 X 20-1/3 Inch13.8 X 9.8 X 13.8 Inch17-3/4 X 17-3/4 X 26 Inch450 X 460 X 510 mm
Number of Tests 100,000 Samples100,000 Samples
Power Source AC Adapter input 100-240V, 50-60 Hz
Sample Capacity 25 μL in Whole Blood (WB) Mode, 70 μL in Pre-dilute (PD) and Body Fluid (BF) Mode25 μL25 μL
Sample Type Whole Blood SampleWhole Blood / Diluted SampleWhole Blood SampleWhole Blood Sample
Test Name WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MPV, NEUT#, NEUT%; IG#, IG%; LYMPH#, LYMPH%; MONO#, MONO%; EO#, EO%; BASO#, BASO%28-Parameter CBC with CBC Differential
Throughput Up to 60 Samples per Hour [Whole Blood (WB) Mode]Up to 57 Samples / HourUp to 60 Samples per HourUp to 60 Samples per Hour (CBC) / Up to 60 Samples per Hour (CBC + DIFF)
Time to Results 1 Minute Results
User Interface LCD Touch Screen OperationColor Touchscreen, Keyboard, MouseColor Touch ScreenTouch Screen Operation
Weight 77.2 lbs.19.8 lbs.117 lbs35 kg
Analyzer Type BenchtopBenchtopBenchtopBenchtopBenchtop
Application Hematology AnalyzerHematology AnalyzerHematology AnalyzerHematology AnalyzerHematology Analyzer
CLIA Classified CLIA Non-WaivedCLIA Non-WaivedCLIA Non-WaivedCLIA Non-WaivedCLIA Non-Waived
Purchase Program Type Standard Purchase AgreementStandard Purchase AgreementStandard Purchase AgreementStandard Purchase AgreementStandard Purchase Agreement
UNSPSC Code 4111581541115815411158154111581541115815
Features and Benefits
  • Open tube sampling
  • Integrated IPU with LCD color touch-screen
  • Intuitive XN software
  • XN-L hematology analyzers feature a small and compact footprint
  • Standardization – XN-L can provide standardized testing from Core lab to satellite labs and affiliated clinics and POLs
  • L-WBC (Low WBC mode) - standard - improves reliability of analysis
  • RET - for enumerated retics and anemia management offering, immature retic fraction (IRF), and reticulocyte hemoglobin (RET-He)
  • XN-BF – (Body Fluid) provides the ability to directly measure body fluids
  • Onboard rules - provide efficient Repeat, Rerun, Reflex based on your own criteria
  • Priced for customers that purchase a 5-year service agreement
  • The CELL-DYN Emerald Hematology System delivers high performance in a compact design, providing results in less than 60 seconds
  • Stores up to 1,500 records with histograms on internal memory; up to 60,000 on external USB thumb drive
  • The CELL-DYN Emerald has easy to use software controlled by a color touchscreen with a built-in keyboard
  • System utilizes electrical impedance for WBC, RBC, and platelet counting and absorption spectrophotometry for hemoglobin
  • Package includes Cell-Dyn Emerald analyzer, UPS, and freight
  • The Sysmex XN-530 Automated Hematology Analyzer is a quantitative multi-parameter automated hematology analyzer intended for in vitro diagnostic use in screening patient populations found in clinical laboratories
  • Principles and Technology: Fluorescent Flow Cytometry (WBC DIFF), DC Impedance method with hydrodynamic focusing (RBC/PLT), Cyanide-free SLS method (HGB)
  • Sample volumes: Whole Blood Mode: 25 μL Pre-dilute Mode: 70 μL
  • Closed sampling system
  • Ability to use elevated bottom vials for the smallest possible sample volume
  • Nozzle made of metal to prevent blood residue on its walls after measurement
  • Nozzle made of metal to prevent blood residue on its walls after measurement
  • Moving average program (X bar M), which uses routine samples in such a way as to ensure continuous control of results
  • Measurement of granulosa (IG) immature cells in absolute number and% for better management of microbial infections and sepsis
  • Measurement of nuclear erythrocytes (NRBC) in absolute number and% for better management of neonatal samples and patients with Mediterranean syndromes
  • Storage capacity of 100,000 samples
  • Storage capacity of 100,000 samples
  • Open tube analysis
  • CBC + DIFF
  • Up to 60 samples/hour