Reconditioned Large Volume Infusion Pump Alaris™ 8100 NonWireless 0.1 to 999 mL / Hr Flow Rate
PUMP, INFUSION ALARIS 8000 REFURB
Features
- Bolus dose channel labels allows a bolus infusion to be programmed using either the Guardrails® drug library or drug calculation feature
- Flow rate accuracy is ± 5% at flow rates = 1 mL/h and from - 8% to + 5 % at flow rates < 1 mL/h.
- Delay options allow system to be programmed to delay start of an infusion: a) For up to 120 minutes or b) for a specific time up to 23 hours 59 minutes
- More …
Product Details Email
Product Specifications
McKesson # | 802227 |
---|---|
Manufacturer # | AM-ALARIS-8100 |
Brand | Alaris™ 8100 |
Manufacturer | Auxo Medical |
Country of Origin | Unknown |
Accuracy Rating | ± 5 % |
Application | Reconditioned Large Volume Infusion Pump |
Connectivity | NonWireless |
Delivery Modes | Pump Mode, Selectable Pressure Mode |
Dimensions | 3.3 X 5.5 X 8.9 Inch |
Drug Library Functionality | Drug Library |
Flow Rate | 0.1 to 999 mL / Hr Flow Rate |
For Use With | Sets:10013037, 2477-0007, 2478-0000, 2477-0006, 2278-0500, 22700-0004, 2279-0006, 10015414, 10062818 |
HCPCS | E0791 |
UNSPSC Code | 42222001 |
Weight | 2.5 lbs. |
Features
- Bolus dose channel labels allows a bolus infusion to be programmed using either the Guardrails® drug library or drug calculation feature
- Flow rate accuracy is ± 5% at flow rates = 1 mL/h and from - 8% to + 5 % at flow rates < 1 mL/h.
- Delay options allow system to be programmed to delay start of an infusion: a) For up to 120 minutes or b) for a specific time up to 23 hours 59 minutes
- Drug calculation allows entry of drug dose and entry of flow rate
- Dynamic pressure display graphically displays current patient-side occlusion pressure set point and current patient-side operating pressure for that module
- Free flow protection utilizes a unique clamping device, the Flo-Stop® device, to prevent inadvertent free-flow when the administration set is removed from the instrument
- Downstream occlusion detection system minimizes nuisance patient side occlusion alarms caused by momentary kinking of tubing, IV pushes, etc
- Guardrails® drug library
- Guardrails® limit
- KVO rate adjust
- Multidose mode
- Occlusion pressure
Frequently Viewed Together
-
,for, Item ID-
- #1250524
-
,for, Item ID-
- #1250527
-
,for, Item ID-
- #1250522
-
,for, Item ID-
- #1250523
-
,for, Item ID-
- #1250532
-
,for, Item ID-
- #1250529
-
,for, Item ID-
- #1250521
-
,for, Item ID-
- #1250526
-
,for, Item ID-
- #1250530
-
,for, Item ID-
- #1250531
-
,for, Item ID-
- #1250528
-
,for, Item ID-
- #1250525
-
,for, Item ID-
- #549815
- BD #2420-0007
-
,for, Item ID-
- #1208851
- B. Braun #4540046-02
-
,for, Item ID-
- #929172
- B. Braun #4540040-02
-
,for, Item ID-
- #929181
- B. Braun #4540008-02