Comparison |
CLIA Classification |
CLIA Non-Waived | CLIA Waived | CLIA Waived | CLIA Waived | CLIA Moderate Complexity |
CLIA Classified |
CLIA Non-Waived | CLIA Waived | CLIA Waived | CLIA Waived | CLIA Non-Waived |
Contents 1 |
Sickle Cell Buffer, Sickle Cell Lysing Reagent, Sickle Cell Urea Agent | (100) Tests per Box, Pipettes, Vials | (50) Test Strips, (60) Pipettes, (1) Code Chip | (50) Test Cartridges, (60) Capilary Tubes, Code Chip | Sickledex Solubility Buffer, Sickledex Solubility Reagent Powder, Dispenser Caps |
Country of Origin |
Unknown | Spain | Unknown | Unknown | United States |
For Use With |
| | For Clarity HbCheck Hemoglobin System | For AimStrip® Hb Hemoglobin Meter | |
Number of Tests |
100 Tests | 100 Tests | 50 Tests | 50 Tests | 100 Tests |
Product Dating |
McKesson Acceptable Dating: we will ship >= 180 days | | | | |
Reading Type |
Visual Read | Visual Read | Machine Read / Visual Read | Machine Read | Visual Read |
Specialty |
Immunoassay | Hematology | Hematology | Hematology | Hematology |
Storage Requirements |
| | | | Requires Refrigeration |
Test Format |
Tube Format | Pipette Format | Test Strip Format / Cartridge Format | Cartridge Format | Tube Format |
Test Kit Type |
Rapid | Standard | Rapid | Rapid | Standard |
Test Name |
Sickle Cell Disease / Sickle Cell Trait | Erythrocyte Sedimentation Rate (ESR) | Hemoglobin | Hemoglobin | Sickle Cell Disease / Sickle Cell Trait |
Test Type |
Solubility Test | Autozero Westergren | Anemia Screen | Anemia Screen | Solubility Test |
Time to Results |
5 Minute Results | 60 Minute Results | 15 Second Results | 15 Second Results | 6 to 60 Minute Results |
UNSPSC Code |
41116120 | 41115815 | 41116120 | 41116120 | 41116120 |
Application |
Hematology Test Kit | Hematology Test Kit | Hematology Test Kit | Hematology Test Kit | Hematology Test Kit |
Purchase Program Type |
Standard Purchase | Standard Purchase | Standard Purchase | Standard Purchase | Standard Purchase |
Sample Type |
Whole Blood Sample | Whole Blood Sample | Whole Blood Sample | Whole Blood Sample | Whole Blood Sample |
Features and Benefits |
- Detects sickle cell in whole blood
- Fast, easy and reliable
- Product characteristics: Detects Hemoglobin S in whole blood
- Sensitivity/Specificity: 99%/ 99%
- Shelf life: 18 months
- SAS™ Sickle Cell Test, detects Hemoglobin S (Hb-S) in whole blood
- Store at Room Temperature 15° - 30° C
|
- Shatter-proof plastic components
- The polystyrene Sedi-Rate™ pipette is graduated from 0 to 180mm and features a unique fibrous plug located at the zero mark
- The plug is specifically designed to be a self-sealing aerosol barrier that stops hazardous substances from escaping through the top of the pipette
- The polypropylene Sedi-Rate™ vial features a patented self-sealing stopper that is easily pierced with a transfer pipette or piercing funnel
- The vial is supplied pre-filled with 0.25mL of 3.8% trisodium citrate diluent
- Simply add 1mL of EDTA-treated blood to complete the 1 to 4 ratio as required by the Westergren method
- CLIA waived test
|
- he Clarity Diagnostics HbCheck Hemoglobin Test Cartridge is used to test hemoglobin which is the main transporter of oxygen in red blood cells
- Measuring hemoglobin concentrations is useful in the clinical diagnosis of diseases, such as anemia and polycythemia
- Acceptable specimens include fresh capillary or venous blood
- Use only Clarity HbCheck Hemoglobin Testing System CLAHB2 - not included
|
- For testing hemoglobin in whole blood
- Combo includes: 50 test cartridges, 60 capillary tubes, 1 code chip
|
- SICKLEDEX detects the presence of sickling hemoglobins in human blood or sickle cell control material
- SICKLEDEX kits are conveniently packaged with two separate squeeze bottles of phosphate buffer with Saponin for easy dispensing and to eliminate waste
- The kits also contain two buffer dispensing caps and two vials of Sodium Hydrosulfite reagent powder
- Each test requires 2.0 mL of reconstituted solubility buffer and 20 µL of anticoagulated whole blood or 20 µL of sickle cell hemoglobin control
|