Product Comparison


  O&M Halyard Inc 89538 McKesson Brand 183-I80-05170G-S McKesson Brand 183-I80-05172G-S McKesson Brand 183-I80-05119G-S McKesson Brand 183-I80-05174G-S
McKesson # 698039 1101288 1101292 1101276 1101307
Description Abdominal Drape Laparoscopic / Cholecystectomy Drape 104 W X 76 W X 102 L Inch Sterile Abdominal Drape McKesson Laparotomy Drape 102 W X 76 W X 120 L Inch Sterile Abdominal Drape McKesson Transverse Laparotomy Drape 100 W X 72 W X 120 L Inch Sterile Abdominal Drape McKesson Pediatric Laparotomy Drape 76 W X 124 L Inch Sterile Abdominal Drape McKesson LAVH Laparotomy Drape 112 W X 30 W X 124 L Inch Sterile
Manufacturer # 89538183-I80-05170G-S183-I80-05172G-S183-I80-05119G-S183-I80-05174G-S
Brand  McKessonMcKessonMcKessonMcKesson
Manufacturer O&M Halyard IncMcKesson BrandMcKesson BrandMcKesson BrandMcKesson Brand
Invoice DRAPE, LAP CHOLESTECTOMY 104X76X120 (25/CS)DRAPE, SURGICAL LAP STR 104"X76"X120" (13/CS)DRAPE, SURG TRANSVERSE LAPAROTOMY STR 100"X72"X120" (14/CS)DRAPE, SURGICAL PED LAPAROTOMYSTR 76"X124" (13/CS)DRAPE, SURGICAL PELVY LAP STR 112"X30"X124" (10/CS)
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

Dimensions 104 W X 76 W X 102 L Inch102 W X 76 W X 120 L Inch100 W X 72 W X 120 L Inch76 W X 124 L Inch112 W X 30 W X 124 L Inch
Drape Name Laparoscopic / Cholecystectomy DrapeLaparotomy DrapeTransverse Laparotomy DrapePediatric Laparotomy DrapeLAVH Laparotomy Drape
Extremity Cover Arm CoversArm CoversArm CoversWithout CoversArm Covers, Attached Leggings
Fluid Collection Type Without PouchWithout PouchWithout PouchWithout PouchFluid Collection Pouch
Latex Free Indicator Not Made with Natural Rubber LatexNot Made with Natural Rubber LatexNot Made with Natural Rubber LatexNot Made with Natural Rubber Latex
Material SMVS Base Panel with Air Laid PadSMS FabricSMS FabricSMS FabricSMS Fabric
Pouch Specifications Suction Port, Graduated Markings, Filtering Screen
Reinforcement Type Absorbent ReinforcementEdgeguard™ Technology Absorbent ReinforcementEdgeguard™ Technology Absorbent ReinforcementEdgeguard™ Technology Absorbent ReinforcementEdgeguard™ Technology Absorbent Reinforcement
Securing Method Adhesive TapeAdhesive TapeAdhesive TapeAdhesive Tape
Surgical Area Specifications Rectangle 12 X 13 inch Abdominal FenestrationRectangle 4 X 12 Icnh FenestratedTransverse 4 X 14 Inch FenestrationRectangle 4 X 6 Inch FenestrationTrapezoidal 7 X 9 Inch Abdominal Fenestration 3 x 8 Inch Perineal Fenestration
Tube and Cord Holders Cord and Tube Holders, Hook and LoopCord and Tube HoldersCord and Tube HoldersCord and Tube HoldersCord and Tube Holders
UNSPSC Code 4213170142131701421317014213172642131701
Application Abdominal DrapeAbdominal DrapeAbdominal DrapeAbdominal DrapeAbdominal Drape
Color BlueBlueBlueBlueBlue
Country of Origin ChinaChinaChinaChinaChina
Instrument Holders Without Instrument HolderWithout Instrument HolderWithout Instrument HolderWithout Instrument HolderWithout Instrument Holder
Sterility SterileSterileSterileSterileSterile
Surgical Area FenestratedFenestratedFenestratedFenestratedFenestrated
Features and Benefits
  • Simple, flexible, easy to use designs
  • Adaptable for multiple procedures
  • Includes equipment covers
  • Meets industry standards for flame-resistance
  • McKesson Laparotomy Drape
  • For use in general procedures
  • Absorbent-reinforcement material provides high rate of absorbency and absorbent capacity
  • Edgeguard® Technology provides precise adhesive edging around the fenestration effectively channelling fluids to the top of the drape absorbent reinforcement and securing drape placement during surgery
  • Specifically designed SMS fabric reinforcement provides fluid repellency, added durability and patient comfort
  • Low-linting SMS fabric properties reduces particle generation - a known source of post-operative complications caused by bacterial transmission or foreign body contamination
  • Flame-resistant polypropylene prevents ignition risks associated with the use of high-energy medical devices during surgery
  • Includes armboard covers to provide effective coverage to patient's upper extremities
  • Includes fabric tube holders for securing tubing and line management
  • Folded drape designs with clear instructional stamps promote ease of use, aseptic presentation, and intuitive drape placement
  • Meets standard for ASTM D5034-2009 for Breaking Strength and Elongation of Textile Fabrics (Grab Test)
  • Meets Class 1 Standard for Flammability of Clothing Textiles 16 CFR Part 1618
  • Meets standard for ISO 9073-10-2003 Textiles, Part 10 for Lint-Resistance
  • Meets standard for ISO 10993 Biocompatibility Testing for Cytotoxicity, Irritation, and Sensitization
  • Meets standard for ISO 12945-2 abrasion resistance
  • Not Made with Natural Rubber Latex
  • Edgeguard® Technology is a trademark of Invenio HealthCare, LLC.
  • Packaged: 1 Drape Per Pack, 13 Packs Per Case
  • McKesson Transverse Laparotomy Drape
  • For use in procedures requiring transversed fenestration
  • Absorbent-reinforcement material provides high rate of absorbency and absorbent capacity
  • Edgeguard® Technology provides precise adhesive edging around the fenestration effectively channeling fluids to the top of the drape absorbent reinforcement and securing drape placement during surgery
  • Specifically designed SMS fabric reinforcement provides fluid repellency, added durability and patient comfort
  • Low-linting SMS fabric properties reduces particle generation - a known source of post-operative complications caused by bacterial transmission or foreign body contamination
  • Flame-resistant polypropylene prevents ignition risks associated with the use of high-energy medical devices during surgery
  • Includes armboard covers to provide effective coverage to patient's upper extremities
  • Includes fabric tube holders for securing tubing and line management
  • Folded drape designs with clear instructional stamps promote ease of use, aseptic presentation, and intuitive drape placement
  • Meets standard for ASTM D5034-2009 for Breaking Strength and Elongation of Textile Fabrics (Grab Test)
  • Meets Class 1 Standard for Flammability of Clothing Textiles 16 CFR Part 1619
  • Meets standard for ISO 9073-10-2003 Textiles, Part 10 for Lint-Resistance
  • Meets standard for ISO 10993 Biocompatibility Testing for Cytotoxicity, Irritation, and Sensitization
  • Meets standard for ISO 12945-2 abrasion resistance
  • Not Made with Natural Rubber Latex
  • Edgeguard® Technology is a trademark of Invenio HealthCare, LLC.
  • Packaged: 1 Drape Per Pack, 14 Packs Per Case
  • McKesson Pediatric Laparotomy Drape
  • For use in general procedures involving a pediatric patient
  • Absorbent-reinforcement material provides high rate of absorbency and absorbent capacity
  • Edgeguard® Technology provides precise adhesive edging around the fenestration effectively channelling fluids to the top of the drape absorbent reinforcement and securing drape placement during surgery
  • Specifically designed SMS fabric reinforcement provides fluid repellency, added durability and patient comfort
  • Low-linting SMS fabric properties reduces particle generation - a known source of post-operative complications caused by bacterial transmission or foreign body contamination
  • Flame-resistant polypropylene prevents ignition risks associated with the use of high-energy medical devices during surgery
  • Includes fabric tube holders for securing tubing and line management
  • Folded drape designs with clear instructional stamps promote ease of use, aseptic presentation, and intuitive drape placement
  • Meets standard for ASTM D5034-2009 for Breaking Strength and Elongation of Textile Fabrics (Grab Test)
  • Meets Class 1 Standard for Flammability of Clothing Textiles 16 CFR Part 1622
  • Meets standard for ISO 9073-10-2003 Textiles, Part 10 for Lint-Resistance
  • Meets standard for ISO 10993 Biocompatibility Testing for Cytotoxicity, Irritation, and Sensitization
  • Meets standard for ISO 12945-2 abrasion resistance
  • Not Made with Natural Rubber Latex
  • Edgeguard® Technology is a trademark of Invenio HealthCare, LLC.
  • Packaged: 1 Drape Per Pack, 13 Packs Per Case
  • McKesson LAVH Laparotomy Drape
  • For use in perineal and gynecological procedures
  • Features a trapezoidal abdominal fenestration and a rectangular perineal fenestration to fit procedural needs
  • Fenestration cover helps isolate surgical sites
  • Absorbent-reinforcement material provides high rate of absorbency and absorbent capacity
  • Edgeguard® Technology provides precise adhesive edging around the fenestration effectively channelling fluids to the top of the drape absorbent reinforcement and securing drape placement during surgery
  • Specifically designed SMS fabric reinforcement provides fluid repellency, added durability and patient comfort
  • Low-linting SMS fabric properties reduces particle generation - a known source of post-operative complications caused by bacterial transmission or foreign body contamination
  • Flame-resistant polypropylene prevents ignition risks associated with the use of high-energy medical devices during surgery
  • Includes attached leggings and armboard covers to provide effective coverage to patient's extremities
  • Includes fabric tube holders for securing tubing and line management
  • Includes fluid collection pouch to contain fluids and suction port allowing fluid drainage for better sterility maintenance, less mess, and convenient disposal
  • Attached fluid collection pouch designed with malleable band to promote efficient fluid control
  • Graduated markings for convenient fluid measurement
  • Mesh screen provides filtering mechanism to isolate particulate matter from fluid collected in pouch
  • Folded drape designs with clear instructional stamps promote ease of use, aseptic presentation, and intuitive drape placement
  • Meets standard for ASTM D5034-2009 for Breaking Strength and Elongation of Textile Fabrics (Grab Test)
  • Meets Class 1 Standard for Flammability of Clothing Textiles 16 CFR Part 1620
  • Meets standard for ISO 9073-10-2003 Textiles, Part 10 for Lint-Resistance
  • Meets standard for ISO 10993 Biocompatibility Testing for Cytotoxicity, Irritation, and Sensitization
  • Meets standard for ISO 12945-2 abrasion resistance