Product Comparison


  Bard Peripheral Vascular 7711700 Teleflex CDC-45703-XP1A Teleflex CDC-45703-P1A Teleflex AK-14703-SP Teleflex CDC-22702-XP1A
McKesson # 326326 892807 777001 465988 1112445
Description Central Venous Catheter Kit Groshong 7 Fr. Single Lumen Central Venous Catheter Kit 16, 18 Gauge Multi Lumen Central Venous Catheter Kit Blue FlexTip* 7 Fr. Triple Lumen Central Venous Catheter Kit Arrow-Howes™ Blue FlexTip* 7 Fr. Triple Lumen Central Venous Catheter Kit Arrowg+ard Blue® 7 Fr. Double Lumen
Manufacturer # 7711700CDC-45703-XP1ACDC-45703-P1AAK-14703-SPCDC-22702-XP1A
Brand    Arrow-Howes™Arrowg+ard Blue®
Manufacturer Bard Peripheral VascularTeleflexTeleflexTeleflexTeleflex
Invoice CATHETER, GROSHONG SNGL LUMEN 7FR BARDMSCVC KIT, MULTI LMN 7FRX20CM (5/CS) AROWINCVC KIT, MULTI LMN PRESS INJ BLU FLEX (5/CS)CATH KIT, CVC 3-LUM 7FR 12" W/CHLOROPREP (5/CS) AROWINCVC KIT, ARROW G+ARD BLU DBL LUMEN 7FR (5/CS)
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

Coating ARROWg+ard Blue PLUS® Antimicrobial Surface TreatmentArrowg+ard Blue Antimicrobial
Contents 1 (1) Multi-Lumen Indwelling Catheter: 7 Fr. X 8 Inch Pressure Injectable Radiopaque Polyurethane with Blue FleXTip®, ARROWg+ard Blue PLUS® Antimicrobial Surface Treatment, Extension Line Clamps, (1) Spring-Wire Guide, Marked: 0.032 Inch dia. X 23-5/8 Inch (Straight Soft Tip on One End - "J'' Tip on Other) with Arrow Advancer™, (1) Catheter: 18 Gauge X 2-1/2 Inch Radiopaque over 20 Gauge RW Introducer Needle, (1) Pressure Transduction Probe, (1) Injection Needle: SafetyGlide™ 22 Gauge X 1-1/2 Inch and 5 mL Luer-Slip Syringe,(1) Injection Needle: SafetyGlide™ 25 Gauge X 1 Inch and 3 mL Luer-Lock Syringe, (1) Introducer Needle: Echogenic 18 Gauge X 2-1/2 Inch XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe,Spring-Wire Guide, Marked: .032 Inch dia. x 23-5/8 Inch (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer™
  • (1) Multi-Lumen Indwelling Catheter: 7 Fr. x 12 Inch (30 cm) Radiopaque Polyurethane with Blue FlexTip*, Extension Line Clamps, Injection Site Caps
  • (1) Spring-Wire Guide: .032 Inch (.81 mm) dia. x 26-13/16 Inch (68 cm)(Straight Soft Tip on One End - "J" Tip on Other)
  • (1) Introducer Needle: 18 Ga. x 2-1/2 Inch (6.35 cm) XTW
  • (1) Catheter: 18 Ga. x 2-1/2 Inch (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle with 5 cc Luer-Slip Syringe
  • (1) Injection Needle: 22 Ga. x 1-1/2 Inch (3.81 cm) and 5 cc Luer-Slip Syringe
  • (1) Injection Needle: 25 Ga. x 1 Inch (2.54 cm) and 3 cc Luer-Lock Syringe
  • (1) Tissue Dilator
  • (1) 1 Applicator Pouch 2% ChloraPrep* One-Step Solution
  • (1) 5 ml Ampule HCl, 1% Lidocaine Solution
  • (1) Suture: 3-0 Braided Silk with Straight Needle
  • (1) Clamp: Catheter
  • (1) Fastener: Catheter Clamp
  • (1) SharpsAway II* Locking Disposal Cup
  • (1) CSR Wrap
  • (1) Drape: 24 Inch x 36
(1) Arrowg+ard Blue® Two-Lumen Catheter: 7 Fr. (2.5 mm OD) X 16 cm, Pressure Injectable, (1) Spring-Wire Guide, Marked: .025 Inch (0.64 mm) dia. X 23-5/8 Inch (60 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer, (1) Catheter: 20 Ga .X 1-3/4 Inch (4.45 cm) Radiopaque over 22 Ga. TW Introducer Needle, (1) Introducer Needle: Echogenic 18 Ga. X 2-1/2 Inch (6.35 cm) RW, (1)Injection Needle: SafetyGlide™1 25 Ga. X 1 Inch (2.54 cm), (1) Blunt Fill Needle: 18 Ga. X 1-1/2 Inch (3.81 cm), (1)Pressure Transduction Probe, (1) Introducer Needle: Echogenic 20 Ga. X 1-1/2 Inch (3.81 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, (1) Injection Needle: SafetyGlide™1 22 Ga. X 1-1/2 Inch (3.81 cm) and 5 mL Luer-Slip Syringe, (1) Syringes: 3 mL Luer-Lock, (1) Tissue Dilator: 8.5 Fr. (2.8 mm) X 10.2 cm, (2) 10 mL Luer-Lock Pre-Filled Saline Syringe, (1) 5 mL 1% Lidocaine HCl Solution and Alcohol Prep, (1) 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with Hi-Lite Orange™ Tint, (1) SecondSite™ Adjustable Hub: Fastener, (1) SecondSite™ Adjustable Hub: Catheter Clamp, (1) SharpsAway® Disposal Cup, (1) SharpsAway® II Locking Disposal Cup, (1) Maximal Barrier Drape™ with 4 Inch Fenestration, (1) Towel, (1) Needle Holder, (1) Safety Scalpel: #11, (1) Checklist/CLIP Sheet, (1) Flow Rate Information Card with Injection Log, (1) Sterile Procedure Sign, (1) Medication Label: 1% Lidocaine, (2) 2 X 2 Inch Gauze Pad, (5) 4 X 4 Inch Gauze Pad, (1) Dressing: Tegaderm®3 10 cm x 12 cm, (1) Impervious Gown, (1) Dressing: BIOPATCH®4, (1) Bouffant Cap, (1) Mask with Eye Shield, (1) Suture: 3-0 Silk with Curved Needle, (1) Tubing±: 20 Inch (50 cm) Extension, (1) HemoHopper® Fluid Receptacle
Contents 2 (1) Tissue Dilator, (2) 10 ml Luer-Lock Pre-Filled Saline Syringe, (1) 3 ml Applicator Pouch, 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint, (1) 5 ml Ampoule HCl, 1% Lidocaine Solution, (1) Foil Pack 62% Alcohol Hand Gel, (1) Fastener: Catheter Clamp, (1) SharpsAway II™ Locking Disposal Cup, (1) SharpsAway® Disposal Cup, (2) CSR Wrap, (1) MaXimal Barrier Drape™ with 4 Inch fenestration, (1) Towel, (1) Needle Holder, (1) Safety Scalpel: #11, (1) Checklist/CLIP Sheet, (1) Flow Rate Information Card with Injection Log, (1) Medication Label: 1% Lidocaine, (1) Sterile Procedure Sign, (1) Dressing: BIOPATCH®4, (1) Dressing: Tegaderm® 10 X 12 cm, (2) Gauze Pad(s): 2 Inch X 2 Inch, (2) Gauze Pad(s): 3 Inch X 3 Inch, (5) Gauze Pad(s): 4 Inch X 4 Inch, (1) Surgical Apparel: Bouffant Cap, (1) Surgical Apparel: Impervious Gown, (1) Surgical Apparel: Mask with Eye Shield, (1) Suture: 3-0 Silk with Curved NeedleCatheter: 18 Ga. x 2-1/2 Inch Radiopaque over 20 Ga. RW Introducer Needle, Pressure Transduction Probe, Injection Needle: SafetyGlide™2 22 Ga. x 1-1/2 Inch and 5 mL Luer-Slip Syringe, Injection Needle: SafetyGlide™2 25 Ga. x 1 Inch and 3 mL Luer-Lock Syringe, : Introducer Needle: Echogenic 18 Ga. x 2-1/2 Inch XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe, Tissue Dilator, 3 ml Applicator Pouch 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint, Suture: 3-0 Silk with Curved NeedleInch with 4 Inch fenestration
  • (1) Safety Scalpel: #11
  • (4) Staple Anchoring Devices
  • (2) Gauze Pad(s): 2 Inch x 2 Inch
  • (5) Gauze Pad(s): 4 Inch x 4 Inch
  • Contents 3 5 ml Ampule HCl, 1% Lidocaine Solution, Fastener: Catheter Clamp, SharpsAway II™ Locking Disposal Cup, 3 CSR Wraps, Maximal Barrier Drape™ with 4 Inch Fenestration, Towel, Needle Holder, Safety Scalpel: #11, CVC Maximal Barrier Guide Card, Flow Rate Information Card with Injection Log, Medication Label: 1% Lidocaine, Sterile Procedure Sign, 2 Gauze Pads: 2 x 2 Inch, 5 Gauze Pads: 4 x 4 Inch, Bouffant Cap, Impervious Gown, Mask with Eye Shield
    Country of Origin MexicoUnknownUnknownUnknownUnknown
    Cuff Type SureCuff Tissue Ingrowth Cuff
    Diameter 7 Fr.16, 18 Gauge7 Fr.7 Fr.7 Fr.
    HCPCS C1769
    Length 2-1/2 Inch, 8 Inch8 Inch12 Inch16 cm
    Material Pressure Injectable Radiopaque PolyurethanePressure Injectable Radiopaque PolyurethaneRadiopaque Polyurethane
    Sterility Sterile
    Style GroshongBlue FlexTip*Blue FlexTip*
    Tube Type Single LumenMulti LumenTriple LumenTriple LumenDouble Lumen
    UNSPSC Code 4222150442221509422215094222150942221509
    Usage Single UseSingle UseSingle UseSingle Use
    User AdultAdultAdult
    Application Central Venous Catheter KitCentral Venous Catheter KitCentral Venous Catheter KitCentral Venous Catheter KitCentral Venous Catheter Kit
    Features and Benefits
    • Peel-Apart Percutaneous Introducer System
    • Extension Line Clamps
    • E or H pattern lumen with 16 / 18 / 18 hole sizes
    • Extension Line Clamps and Injection Site Caps
    • Pressure injectable Arrowg+ard Blue® Two-Lumen CVC