Comparison |
Application |
Hematology Reagent Microcuvette | Hematology Reagent Microcuvette | General Chemistry Reagent Microcuvette | Hematology Reagent Microcuvette |
CLIA Classification |
CLIA Waived | CLIA Waived | | |
CLIA Classified |
CLIA Waived | CLIA Waived | | |
Container Type |
| Vial | Individually Wrapped | Individually Wrapped |
Country of Origin |
Germany | Unknown | Unknown | Unknown |
For Use With |
For HemoPoint H2 Hemoglobin Photometer | For HemoCue Photometers | For HemoCue Glucose 201 Analyzer | For HemoCue Photometers |
HCPCS |
| | A9275 | |
Number of Tests |
50 Tests | 50 Microcuvettes per Vial | 50 Tests | 100 Tests |
Product Dating |
| McKesson Acceptable Dating: we will ship >= 180 days | McKesson Acceptable Dating: we will ship >= 90 days | |
Sample Type |
Whole Blood Sample | Blood Sample | Blood Sample | Blood Sample |
Specialty |
Hematology | Hematology | General Chemistry | Hematology |
Storage Requirements |
| | Requires Refrigeration | |
Test Category |
Hematology | Anemia | Glucose | Anemia |
Test Format |
Microcuvette | | Microcuvette | Microcuvette |
Test Name |
Hemoglobin (Hb) / Hematocrit | Hemoglobin (Hb) | Glucose | Hemoglobin (Hb) |
Test Type |
| | Diabetes Management | |
UNSPSC Code |
41115816 | 41116205 | 41116205 | 41115816 |
Volume |
| 10 μL | 50 Microcuvettes | 10 μL |
Features and Benefits |
- 1 carton of individually foil wrapped microcuvettes
- Pre-fille cuvette with dry reagent
- Suitable for challenging climate conditions
- Each cuvette package contains its own desiccant
|
- The disposable microcuvette is made of plastic and comprises a body having a cavity which takes about 10 µL
- The cuvette cavity contains reagents deposited on its inner walls and the blood sample is drawn into the cavity by capillary action and spontaneously mixed with the reagents
- The reagents within the microcuvettes are moisture sensitive
- Replace the cap immediately after microcuvettes are removed from the container
- The microcuvettes are to be stored at 15-30 degrees C (59 - 86 degrees F) in a dry place
- Once the vial is opened the microcuvettes are stable for three months
- The disposable microcuvette is made of plastic and comprises a body having a cavity which takes about 10 µL
|
- Individually wrapped microcuvettes
- Professional use only - not for home use
|
- Produce accurate results in less than a minute
- The disposable microcuvette is made of plastic
- Utilizes only 10 mcl of capillary, venous or arterial blood
- The cuvette cavity contains reagents deposited on its inner walls and the blood sample is drawn into the cavity by capillary action
- The microcuvette is placed into either the HemoCue Hb 201+ Analyzer, Hb 201 DM Analyzer or B-Hemoglobin photometer where the absorbance is measured and the hemoglobin level is determined
- Individually pouched microcuvettes
|