QUICK CHECK* H100 Sterilization Wrap White / Blue 40 X 40 Inch Dual Layer SMS Polypropylene Steam / EO Gas / Hydrogen Peroxide

WRAP, STRLZ CSR QUICK CHECK 40X40 KC100 (24/BG 5BG/CS)

Features

  • H100 grade is for use with light linen packs, linen gowns, towel packs, single basins and other lighter wrapping needs - for 0 to 3 lbs tray weight
  • HALYARD* Sterilization Wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider using: Pre-vacuum steam at 270°F/132°C for 4 minutes, 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative humidity for 60 minutes, Lumen, Non Lumen and Flexible Cycles in the STERIS V-PRO® 1, STERIS V-PRO® 1 Plus and STERIS V-PRO® maX Low Temperature Sterilization Systems, Gravity steam at 250°F/121°C for 30 minutes (25 minute dry time for Models 100, 200 and 300 and 30 minute dry time for Models 400, 500 and 600), and Advanced Sterilization Products STERRAD® Sterilization Systems: STERRAD® 50, 100S and 200, STERRAD® NX [Standard Cycle, Advanced Cycle], STERRAD® 100NX [Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle)
  • Do not use wrap in dry heat or radiation sterilization methods
  • More …
Dimensions
12 X 12 Inch 15 X 15 Inch 18 X 18 Inch 20 X 20 Inch 24 X 24 Inch 30 X 30 Inch 36 X 36 Inch 40 X 40 Inch 45 X 45 Inch 48 X 48 Inch 54 X 54 Inch
  Log In to Order
or

Product Specifications


Features
  • H100 grade is for use with light linen packs, linen gowns, towel packs, single basins and other lighter wrapping needs - for 0 to 3 lbs tray weight
  • HALYARD* Sterilization Wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider using: Pre-vacuum steam at 270°F/132°C for 4 minutes, 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative humidity for 60 minutes, Lumen, Non Lumen and Flexible Cycles in the STERIS V-PRO® 1, STERIS V-PRO® 1 Plus and STERIS V-PRO® maX Low Temperature Sterilization Systems, Gravity steam at 250°F/121°C for 30 minutes (25 minute dry time for Models 100, 200 and 300 and 30 minute dry time for Models 400, 500 and 600), and Advanced Sterilization Products STERRAD® Sterilization Systems: STERRAD® 50, 100S and 200, STERRAD® NX [Standard Cycle, Advanced Cycle], STERRAD® 100NX [Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle)
  • Do not use wrap in dry heat or radiation sterilization methods