-
,for, Item ID-
- #914036
- Siemens #10380948
Immunoassay Reagent Immulite® BR-MA (CA15-3) For Immulite / Immulite 1000 Systems 100 Tests
BR-MA CA/15-3 RGT 100/BX IMMULITE 1000 SMHCDG
No Image
Features
- For Quantitative measurement of CA15-3 antigen in human serum, as an aid in the detection of recurrence in previously treated stage II in the management of metastatic breast cancer patients by monitoring disease progression or response to treatment
- Serial testing for patient CA15-3 values should be used in conjunction with other clinical methods used for detecting early recurrence in stage II and stage III disease and for monitoring response to treatment in patients with metastatic breast cancer
- Incubation Cycles: 2 × 30 minutes
- More …
Product Details Email
Product Specifications
McKesson # | 914036 |
---|---|
Manufacturer # | 10380948 |
Brand | Immulite® |
Manufacturer | Siemens |
Country of Origin | United Kingdom |
Alternate Manufacturer Number | LKBR1 |
Application | Immunoassay Reagent |
For Use With | For Immulite / Immulite 1000 Systems |
Form | Liquid |
Number of Tests | 100 Tests |
Sample Type | Serum Sample |
Specialty | Immunoassay |
Storage Requirements | Requires Refrigeration |
Test Category | Cancer Screening |
Test Method | Two-step Sequential Chemiluminescent Immunometric Assay |
Test Name | BR-MA (CA15-3) |
Test Type | Tumor Marker Assay |
UNSPSC Code | 41116010 |
Features
- For Quantitative measurement of CA15-3 antigen in human serum, as an aid in the detection of recurrence in previously treated stage II in the management of metastatic breast cancer patients by monitoring disease progression or response to treatment
- Serial testing for patient CA15-3 values should be used in conjunction with other clinical methods used for detecting early recurrence in stage II and stage III disease and for monitoring response to treatment in patients with metastatic breast cancer
- Incubation Cycles: 2 × 30 minutes
- Volume Required: 5 µL serum (Sample cup must contain at least 100 µL more than the total volume required)
Professionals Also Viewed
-
,for, Item ID-
- #931479
- BD #441126
- Qualitative detection of Chlamydia trachomatis DNA in clinician-collec …
No Image
-
,for, Item ID-
- #807130
- Providers like you icon 145
- Ortho Clinical Diagnostics #1142561
- VITROS Immunodiagnostic Products Vitamin B12/Folate Reagent Pack 3
- For use in conjunction with the VITROS Vitamin B12 and VITROS Folate R …
- VITROS Vitamin B12/Folate Reagent Pack 3 contains: 11.7 mL sample trea …
-
,for, Item ID-
- #861548
- Providers like you icon 69
- Abbott #06C0627
- The ARCHITECT Total PSA assay is a Chemiluminescent Microparticle Immu …
-
,for, Item ID-
- #1107738
- Providers like you icon 68
- Abbott #07K6529
- The ARCHITECT Free T4 (FT4) assay is a Chemiluminescent Microparticle …
Related Products
-
,for, Item ID-
- #917787
- Siemens #10380058
- Over 100 outside the U.S. (90 U.S.) assays for routine and esoteric te …
- The reliability and ease-of-use makes the IMMULITE 1000 system particu …
- Dependable operation provides laboratories with confidence: The reliab …
-
,for, Item ID-
- #925111
- Siemens #10373214
- User-defined automatic dilution protocols
- Five hours of usable walkaway time
- Third-generation assays for excellent sensitivity