Comparison |
Alternate Manufacturer Number |
030006-03 | | | | |
Analyzer Type |
Benchtop | Benchtop | Benchtop | Benchtop | Floorstanding |
Application |
Immunoassay Analyzer | Fluorescent Immunoassay Analyzer | Immunoassay Analyzer | Immunoassay Analyzer | Integrated Chemistry / Immunoassay Analyzer |
Automation Type |
| | Automated | Automated | Automated |
CLIA Classification |
| CLIA Waived | CLIA Moderate / High Complexity | CLIA Moderate / High Complexity | |
CLIA Classified |
CLIA Non-Waived | CLIA Waived | CLIA Non-Waived | CLIA Non-Waived | CLIA Non-Waived |
Contents 1 |
| 1 Purchased Sofia 2 Analyzer | | Monitor, Rental Agreement Program | |
Country of Origin |
United States | Australia | Unknown | Unknown | United States |
Dimensions |
19 X 26 X 46 Inch | 12 X 12 X 22 cm | 18.5 X 39 X 24 Inch | 18.5 X 24 X 39 Inch | 50 X 57-1/5 X 59 Inch |
Number of Tests |
| | | 50 Tests | |
Power Source |
110 to 120 V, 6 A/200 to 240 V, 4 A, 50/60 Hz Powered | 100 to 240 VAC, 50/60 Hz | 115/120 VAC, 15 A | 115/120 VAC, 15 A | 200 to 240 VAC, 50/60 Hz |
Purchase Program Type |
Standard Purchase Agreement | Standard Purchase Agreement | Standard Purchase Agreement | Rental Agreement | Standard Purchase Agreement |
Readout Type |
15 Inch Display | Digital and Printout | | | |
Sample Capacity |
| | Up to 60 Sample Capacity | 5 to 250 µL | |
Sample Type |
Serum / Plasma Sample | Sample Dependent on Test Performed | Whole Blood / Serum / Plasma / Urine / Amnionic Fluid Sample | Whole Blood / Serum / Plasma / Urine / Amnionic Fluid Sample | Whole Blood / Serum / Plasma / Urine / Amniotic Fluid Sample |
Test Name |
Allergy, Anemia, Bone Metabolism, Cardiac, Diabetes, Growth, Hepatitis, Inflammation, Metabolic, Oncology, Reproductive Endocrinology, Special ID, Therapeutic Drug Monitoring (TDM), Thyroid, ToRCH, Veterinary, Other | Influenza A + B, Respiratory Syncytial Virus (RSV) | | Adrenal/Pituitary, Allergy, Anemia, Bone Metabolism, Cardiovascular, Diabetes, Infectious Disease, Reproductive, Thyroid, Tumor Markers | Anemia, Autoimmune, Bone Metabolism, Cardiac, Diabetes, Growth, Hepatitis, HIV, Immunosuppressant Drugs, Inflammation, Metabolic, Oncology, Reproductive Endocrinology, Sepsis, Special ID, Therapeutic Drug Monitoring, Thyroid and TORCH |
Throughput |
120 Tests per Hour | | Up to 100 Tests per Hour | Up to 100 Tests per Hour | Up to 220 Tests per Hour |
Time to Results |
42 Minute Results (Standard Mode), 15 Minute Results (Turbo Mode) | 15 Minute Results | | | 10 to 54 Minute Assay-Dependent Results |
UNSPSC Code |
41115819 | 41115821 | 41115819 | 41115819 | 41115819 |
User Interface |
Touch Screen, Micro-Keyboard | Touchscreen Display | 19 Inch Touch-Screen Monitor | 19 Inch Touch Screen Monitor | |
Weight |
240 lbs. | 2 lbs. | 200 lbs. | 200 lbs. | 1308 lbs. |
Features and Benefits |
- Over 100 outside the U.S. (90 U.S.) assays for routine and esoteric testing, increases the lab's in-house testing capabilities
- The reliability and ease-of-use makes the IMMULITE 1000 system particularly well suited for use in remote laboratories throughout the world
- Dependable operation provides laboratories with confidence: The reliability allows laboratories confidence in assay turnaround times; cost of ownership is low due to minimal service, operator interventions, and operator time
- Improving laboratory efficiency through the ease of use: Few consumables; daily maintenance in less than 10 minutes; sample and reagent level sensors; easy entry of assay parameters, expiration dates, and calibration adjustment intervals; integration of the computer, keyboard, and monitor provide a consolidated footprint
- Flexible solutions to adapt to a laboratory's needs: Throughput up to 120 tests per hour; turbo assays (troponin I, CK-MB, myoglobin, intact PTH, and HCG) allow results in 15 Minute for critical tests; 12 position reagent carousel
- Random access immunoassay system
- Indirect tube sampling; liquid level sensors
- Code 38, code 128, codabar, and I-2 of 5 (Interleaved) format barcodes
- Allows operator to auto load calibration information and test parameters
- Microsoft® Windows® 7 operating system
- 18 to 32°C Operating temperature
|
- Manufacturer contract required before item can be shipped
- Sofia 2 is a small bench top analyzer that uses advanced fluorescence detection with an ultraviolet LED energy source
- Sofia 2 collects hundreds of data points on the test strip contained inside of a Sofia FIA Test Cassette
- Sofia 2 uses proprietary algorithms to analyze the data, interpret the signals and determine the results automatically to give you an objective result you can rely on
- Power supply input : 100-240 VAC, 50-60 Hz, self-switching (U.S./ International), 2.93
- Analyzer input: 7.5V DC 2.5A
- Replacement battery: Li Po rechargeable
|
- The Access 2 was designed to have the robustness of a reference-lab immunoassay analyzer in the convenient size of a bench-top instrument
- The Access 2 delivers an extensive immunoassay diagnostic-testing menu that includes sTfR in our anemia panel as well as SHBG and Testosterone in our comprehensive reproductive panel
- With an intuitive operator interface, enhanced sample handling and innovative menu, the state-of-the-art Access 2 system delivers new levels of laboratory efficiency, standardization and cost effectiveness
- A broad menu of high quality assays from Beckman Coulter, plus new, productivity-enhancing features on the Access 2 offer laboratories a flexible option for immunoassay testing
- New touch-panel user interface improves data and sample management
- View rack and run completion time on screen, in real time
- Perform user-defined reflex testing to eliminate repetitive, manual processes
- Check status of required supplies
- Runs on Windows® NT software
- Link up to four systems through a single LIS interface for greater efficiency
- Streamline workflow with the system's flexible sample handling, using bar-coded primary and/or aliquot tubes
- Magnetic particle separation with chemiluminescent detection technology achieves wide analytical range and fast assay processing
- Twenty-four resident assays with continuous random access and STAT capability
- On-board refrigeration enhances reagent stability
- The Access 2 Immunoassay System has been categorized as moderately complex for all assays, with the following exceptions, which are highly complex: Folate (red blood cell), Cortisol Urine (extraction procedure), and AFP for Open Neural Tube Defect (ONTD); serum and amniotic fluid
|
- > Over 50 Available immunoassay diagnostic assays
- Multiple assays available in the diagnostic specialties you need most
- Continuous menu expansion with new and novel assays
- On board refrigeration storage of up to 24 assays
- Up to 56-day reagent open-pack stability
- One-year reagent shelf life (typical)
- Load up to 60 samples at one time
- Dioxetane-based chemiluminescence (Lumi-Phos) magnetic particle separation
- Luminometer chemiluminescent detector
- STAT and automatic reflex testing
|
- Atellica IM 1300 Analyzer, mid-volume analyzer with Acridinium Ester (AE) Technology
- Flexible, scalable, automation-ready immunoassay and clinical chemistry analyzer engineered to deliver control and simplicity
- 42 primary assay positions, 35 ancillary reagent positions
- Engineered to be highly reliable for high productivity within a small footprint, features built-in temperature control, automatic quality control (QC) when connected to the Atellica® Sample Handler, workflow enhancements to reduce operator intervention, and a broad and expanding menu across disease states
- Atellica IM analyzers use the same reagents and consumables in every configuration for streamlined inventory management and consistent patient results, no matter where the samples are tested
- Sandwich, competitive, and antibody-capture/antigen-bridge formats
- Reagent pack bar-code identification; automatic tracking and notification of inventory, calibration and control validity, onboard stability, low and expired reagents, detection of reagent bubbles
- Removable Media: USB
|