  Teleflex LLC 28052 McKesson Brand 16-6220 McKesson Brand 16-6221 McKesson Brand 16-6218 McKesson Brand 16-6379
McKesson # 486454 1109626 1109629 1109620 1109633
Description Heat and Moisture Exchanger with Filter Iso-Guard 25, Vt = .25 L 2.3 LPM Heat and Moisture Exchanger with Filter McKesson 29.2 mg H2O / L @ VT 500 mL 2.5 cm H20 @ 30 LPM Heat and Moisture Exchanger with Filter McKesson 32.1 mg H2O / L @ VT 500 mL 2.5 cm H20 @ 30 LPM Heat and Moisture Exchanger with Filter McKesson 28.4 mg H2O / L @ VT 500 mL 2.29 cm H20 @ 30 LPM, 0.25 cm H20@ 8 LPM Heat and Moisture Exchanger with Filter McKesson 32.1 mg H2O / L @ VT 500 mL 1.69 cm H20 @ 30 LPM
Manufacturer # 2805216-622016-622116-621816-6379
Brand Iso-GuardMcKessonMcKessonMcKessonMcKesson
Manufacturer Teleflex LLCMcKesson BrandMcKesson BrandMcKesson BrandMcKesson Brand
Invoice FILTER, ISO-GARD HEPA ANGL SM (25/CS) TELFLXHMEF, IN-LINE MINI ADLT (50PK/CS)HMEF, IN-LINE MAXI ADLT (50PK/CS)HMEF, ANGLED INLET ADLT (50PK/CS)HMEF, IN-LINE MAXI CO2 PORT ADLT (50PK/CS)
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

Connection Type 15 M22 mm O.D. / 15 mm I.D. x 22 mm I.D. / 15 mm O.D. Port22 mm O.D. / 15 mm x 22 mm I.D. Port22 mm O.D. / 15 I.D. x 15 O.D. mm Port22 mm O.D. / 15 mm x 22 mm I.D. Port
Country of Origin UnknownMexicoMexicoMexicoMexico
Dead Space 29.24 mL26.77 mL49.15 mL28.3 mL49.15 mL
Filter Efficiency BFE 99.9999%99.9%99.9%99.9%99.9%
Filter Efficiency VFE 99.9999%99.9%99.9%99.9%99.9%
Filter Type HEPAHygroscopicHygroscopicHygroscopicHygroscopic
Is_ECAT NNNN
Is_GSA NNNN
Is_VA YYYY
Latex Free Indicator Not Made with Natural Rubber LatexNot Made with Natural Rubber LatexNot Made with Natural Rubber LatexNot Made with Natural Rubber Latex
Moisture Output 25, Vt = .25 L29.2 mg H2O / L @ VT 500 mL32.1 mg H2O / L @ VT 500 mL28.4 mg H2O / L @ VT 500 mL32.1 mg H2O / L @ VT 500 mL
Resistance 2.3 LPM2.5 cm H20 @ 30 LPM2.5 cm H20 @ 30 LPM2.29 cm H20 @ 30 LPM, 0.25 cm H20@ 8 LPM1.69 cm H20 @ 30 LPM
Size Maxi
Style AngledStraightStraightAngledStraight
User Adult / Pediatric / NeonatalAdultAdultAdultAdult
Volume 150 to 800 mL150 to 1000 mL350 to 1500 mL150 to 1000 mL350 to 1500 mL
Weight 22.33 Gram
Application Heat and Moisture Exchanger with FilterHeat and Moisture Exchanger with FilterHeat and Moisture Exchanger with FilterHeat and Moisture Exchanger with FilterHeat and Moisture Exchanger with Filter
Port Type Gas Sampling PortGas Sampling PortGas Sampling PortGas Sampling PortGas Sampling Port
Sterility NonSterileNonSterileNonSterileNonSterileNonSterile
UNSPSC Code 4227221942272219422722194227221942272219
Features and Benefits
  • Small, angled
  • ISO-GARD HEPA Small filtered HME systems utilize the same, proven bi-directional bacterial/viral filtration media used in the larger HEPA Light models, at half the size for optimal anesthesia applications
  • High-level filtration protection while conserving patient exhaled heat and humidity
  • Ideal for adult and pediatric patients in the anesthesia arena
  • Smooth, lightweight, transparent, low dead space housing design for maximum patient and staff comfort
  • True hydrophobic HEPA filter, HEPA Class 13
  • Bacterial/viral filtration efficiency: 99.9999+%
  • With CO2 monitoring port, luer cap and cap docking station
  • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • McKesson Mini In-Line Heat and Moisture Exchanger with CO2 Port
  • Mini design allows tidal volumes from 150 mL - 1000 mL for broad use among children and adults
  • In-line design allows for use with gas elbow to fit to fit user preference
  • For short-term airway humidification
  • For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
  • Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
  • Bacterial/viral filtration efficiencies in excess of 99.9%
  • High moisture retention characteristics
  • Clear housing to view levels of humidification
  • Provide superior moisture output, minimum size, low breathing resistance
  • True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
  • Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
  • Low resistance to airflow minimizes work of breathing
  • Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • End tidal CO2 sampling port offers convenient access to airway gases
  • Luer gas sampling ports for secure connection
  • ISO-standard connections for secure, leak-resistant attachment to breathing systems
  • Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used
  • Disposable available in convenient case quantities and individually-wrapped for single patient use
  • Not Made with Natural Rubber Latex
  • 1 Per Pack, 50 Packs Per Case
  • McKesson Maxi In-Line Heat and Moisture Exchanger
  • Maxi design for adult use with greater tidal volumes ranging from 350 mL to 1500 mL
  • In-line design allows for use with gas elbow to fit to fit user preference
  • For short-term airway humidification
  • For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
  • Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
  • Bacterial/viral filtration efficiencies in excess of 99.9%
  • High moisture retention characteristics
  • Clear housing to view levels of humidification
  • Provide superior moisture output, minimum size, low breathing resistance
  • True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
  • Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
  • Low resistance to airflow minimizes work of breathing
  • Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • End tidal CO2 sampling port offers convenient access to airway gases
  • Luer gas sampling ports for secure connection
  • ISO-standard connections for secure, leak-resistant attachment to breathing systems
  • Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used
  • Disposable available in convenient case quantities and individually-wrapped for single patient use
  • Not Made with Natural Rubber Latex
  • 1 Per Pack, 50 Packs Per Case
  • McKesson Angled Inlet Heat and Moisture Exchanger with CO2 Port
  • Mini design allows tidal volumes from 150 mL - 1000 mL for broad use among children and adults
  • Angled inlet eliminates need for gas sampling elbow
  • For short-term airway humidification
  • For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
  • Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
  • Bacterial/viral filtration efficiencies in excess of 99.9%
  • High moisture retention characteristics
  • Clear housing to view levels of humidification
  • Provide superior moisture output, minimum size, low breathing resistance
  • True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
  • Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
  • Low resistance to airflow minimizes work of breathing
  • Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • End tidal CO2 sampling port offers convenient access to airway gases
  • Luer gas sampling ports for secure connection
  • ISO-standard connections for secure, leak-resistant attachment to breathing systems
  • Disposable available in convenient case quantities and individually-wrapped for single patient use
  • Not Made with Natural Rubber Latex
  • 1 Per Pack, 50 Packs Per Case
  • McKesson Maxi In-Line Heat and Moisture Exchanger with Port
  • Maxi design for adult use with greater tidal volumes ranging from 350 mL to 1500 mL
  • In-line design allows for use with gas elbow to fit to fit user preference
  • For short-term airway humidification
  • For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
  • Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
  • Bacterial/viral filtration efficiencies in excess of 99.9%
  • High moisture retention characteristics
  • Clear housing to view levels of humidification
  • Provide superior moisture output, minimum size, low breathing resistance
  • True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
  • Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
  • Low resistance to airflow minimizes work of breathing
  • Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • Designed with no port to eliminate risks of a possible leak point
  • ISO-standard connections for secure, leak-resistant attachment to breathing systems
  • Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used
  • Disposable available in convenient case quantities and individually-wrapped for single patient use
  • Not Made with Natural Rubber Latex
  • 1 Per Pack, 50 Packs Per Case