Product Comparison


  Beckman Coulter B98654 Beckman Coulter B98656 Beckman Coulter B86444
McKesson # 1062320 1062318 1197396
Description Chemistry Analyzer with ISE DxC 700 AU CLIA Non-Waived Chemistry Analyzer with ISE DxC 700 AU DTS CLIA Non-Waived Chemistry Analyzer with ISE DxC 700 AU CLIA Non-Waived
Manufacturer # B98654B98656B86444
Brand DxC 700 AUDxC 700 AU DTSDxC 700 AU
Manufacturer Beckman CoulterBeckman CoulterBeckman Coulter
Invoice ANALYZER, DXC 700AU W/ISE D/SANALYZER, DXC 700AU DTSC W/ISED/SANALYZER, CHEMISTRY DXC700 AU W/ISE SALE GROUP D/S
    Log In to Order   Log In to Order   Log In to Order

Comparison

Contents 1 ISE Sales GroupWithout ISE Sales GroupDxC700 AU with ISE Sales Group
Country of Origin United StatesUnited StatesJapan
Analyzer Type FloorstandingFloorstandingFloorstanding
Application Chemistry Analyzer with ISEChemistry Analyzer with ISEChemistry Analyzer with ISE
Automation Type AutomatedAutomatedAutomated
CLIA Classified CLIA Non-WaivedCLIA Non-WaivedCLIA Non-Waived
Dimensions 35 X 49 X 51 Inch35 X 49 X 51 Inch35 X 49 X 51 Inch
Number of Tests 120 Tests120 Tests120 Tests
Power Source 200 to 240 V, 50/60 Hz, 3.8 kVA200 to 240 V, 50/60 Hz, 3.8 kVA200 to 240 V, 50/60 Hz, 3.8 kVA
Purchase Program Type Standard Purchase AgreementStandard Purchase AgreementStandard Purchase Agreement
Sample Capacity 1 to 25 μL in 0.1 μL Increments1 to 25 μL in 0.1 μL Increments1 to 25 μL in 0.1 μL Increments
Sample Type Whole Blood (HbA1c) / Serum / Plasma / Urine / Other Fluids SampleWhole Blood (HbA1c) / Serum / Plasma / Urine / Other Fluids SampleWhole Blood (HbA1c) / Serum / Plasma / Urine / Other Fluids Sample
Test Name Lipemia, Hemolysis and Icterus Indices Clot Detection and Probe Crash Protection, 117 Photometrics (113 + LIH + HbA1c (Thb, HbA1c + HbA1c%)) and ISELipemia, Hemolysis and Icterus Indices Clot Detection and Probe Crash Protection, 117 Photometrics (113 + LIH + HbA1c (Thb, HbA1c + HbA1c%)) and ISELipemia, Hemolysis and Icterus Indices Clot Detection and Probe Crash Protection, 117 Photometrics (113 + LIH + HbA1c (Thb, HbA1c + HbA1c%)) and ISE
Throughput 800 Tests per Hour (Photometric) / Up to 1200 Tests per Hour (with ISE) / 200 Tests per Hour (ISE Sample) / 600 Tests per Hour (ISE Only, Maximum)800 Tests per Hour (Photometric) / Up to 1200 Tests per Hour (with ISE) / 200 Tests per Hour (ISE Sample) / 600 Tests per Hour (ISE Only, Maximum)800 Tests per Hour (Photometric) / Up to 1200 Tests per Hour (with ISE) / 200 Tests per Hour (ISE Sample) / 600 Tests per Hour (ISE Only, Maximum)
Time to Results Up to 8 Minutes 33 Second ResultsUp to 8 Minutes 33 Second ResultsUp to 8 Minutes 33 Second Results
UNSPSC Code 411158074111580741115807
Weight 1015 lbs.1015 lbs.1015 lbs.
Features and Benefits
  • The DxC 700 AU delivers increased uptime, high reliability and precise performance to mid- to large-sized laboratories and hospitals. Its flexible design offers standalone operation or connectivity to laboratory automation systems; with throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the DxC 700 AU delivers reliability and efficiency to laboratories around the world
  • Fully automated, random-access clinical chemistry system with STAT capability
  • Spectrophotometry and potentiometry analytical principles
  • Colorimetry, turbidimetry, latex agglutination and indirect ISE analytical methods
  • Endpoint, rate, fixed point and indirect ISE assay types
  • Sampler capacity rack sampler: 10 samples per rack (barcodes on primary tubes and on racks), capacity for 150 samples, refrigerated STAT carousel: 22 samples can be run simultaneously (cal, QC and routine samples)
  • Wavelength: 13 Different wavelengths between 340 nm and 800 nm
  • 0 to 3 OD Photometric range
  • Dry bath reaction method
  • Permanent glass cuvettes reaction cuvette
  • 150 Sample continuous rack loader
  • Economical ISE's with long onboard stability; easy-to-maintain (only individual electrode replacement required)
  • Priority sample repeat/reflex
  • Ability to load reagents while the analyzer is in measure mode
  • Cooled STAT compartment, providing one-button STAT interrupt, advanced auto QC and calibration capabilities
  • The DxC 700 AU delivers increased uptime, high reliability and precise performance to mid- to large-sized laboratories and hospitals. Its flexible design offers standalone operation or connectivity to laboratory automation systems; with throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the DxC 700 AU delivers reliability and efficiency to laboratories around the world
  • Fully automated, random-access clinical chemistry system with STAT capability
  • Spectrophotometry and potentiometry analytical principles
  • Colorimetry, turbidimetry, latex agglutination and indirect ISE analytical methods
  • Endpoint, rate, fixed point and indirect ISE assay types
  • Sampler capacity rack sampler: 10 samples per rack (barcodes on primary tubes and on racks), capacity for 150 samples, refrigerated STAT carousel: 22 samples can be run simultaneously (cal, QC and routine samples)
  • Wavelength: 13 Different wavelengths between 340 nm and 800 nm
  • 0 to 3 OD Photometric range
  • Dry bath reaction method
  • Permanent glass cuvettes reaction cuvette
  • 150 Sample continuous rack loader
  • Economical ISE's with long onboard stability; easy-to-maintain (only individual electrode replacement required)
  • Priority sample repeat/reflex
  • Ability to load reagents while the analyzer is in measure mode
  • Cooled STAT compartment, providing one-button STAT interrupt, advanced auto QC and calibration capabilities
  • The DxC 700 AU delivers increased uptime, high reliability and precise performance to mid- to large-sized laboratories and hospitals. Its flexible design offers standalone operation or connectivity to laboratory automation systems; with throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the DxC 700 AU delivers reliability and efficiency to laboratories around the world
  • Fully automated, random-access clinical chemistry system with STAT capability
  • Spectrophotometry and potentiometry analytical principles
  • Colorimetry, turbidimetry, latex agglutination and indirect ISE analytical methods
  • Endpoint, rate, fixed point and indirect ISE assay types
  • Sampler capacity rack sampler: 10 samples per rack (barcodes on primary tubes and on racks), capacity for 150 samples, refrigerated STAT carousel: 22 samples can be run simultaneously (cal, QC and routine samples)
  • Wavelength: 13 Different wavelengths between 340 nm and 800 nm
  • 0 to 3 OD Photometric range
  • Dry bath reaction method
  • Permanent glass cuvettes reaction cuvette
  • 150 Sample continuous rack loader
  • Economical ISE's with long onboard stability; easy-to-maintain (only individual electrode replacement required)
  • Priority sample repeat/reflex
  • Ability to load reagents while the analyzer is in measure mode
  • Cooled STAT compartment, providing one-button STAT interrupt, advanced auto QC and calibration capabilities