Product Comparison


 
Teleflex ASK-01000-CHP
Smiths Medical 4653-48
Med-Tech Resources MTR-THOR1
Med-Tech Resources MTR-THOR2
Cardinal 566075
McKesson # 922604 208975 853862 853863 453736
Description Thoracentesis Set Arrow-Clarke® Pleura-Seal® Pleura-Seal Thoracentesis Set Portex® Single Use Thoracentesis Set Thoracentesis Set Thoracentesis Set Turkel® Sterile
Manufacturer # ASK-01000-CHP4653-48MTR-THOR1MTR-THOR2566075
Brand Arrow-Clarke® Pleura-Seal®Portex®  Turkel®
Manufacturer TeleflexSmiths MedicalMed-Tech ResourcesMed-Tech ResourcesCardinal
Invoice THORACENTESIS TRAY, W/SHARPS SAFETY PLEURA-SEAL (10/CS)THORACENTESIS SET, (48/CS)THORACENTESIS KIT, EMERGENCY W/IV CATHTHORACENTESIS KIT, EMERGENCY W/ANGIOCATHTHORACENTESIS TRAY, LONG SAFETY (5/CS) KENDAL
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

Contents Polyurethane Centesis Device: 8 Fr. Catheter over 18 Ga. x 7-1/2" (19 cm) RW Needle with 3-way Stopcock Self-Sealing Valve and 5 mL Luer-Lock Syringe, (1) Injection Needle: 22 Ga. x 1-1/2 Inch (3.81 cm), (1) Injection Needle: 25 Ga. x 1 Inch (2.54 cm), (1) Syringe: 10 mL Luer-Lock One: Syringe: 60 mL Luer-Lock One: Tubing Set with Aspiration/Discharge Device - One: 3 ml Applicator Pouch, 2% CHG and 70% IPA ChloraPrep®Male Adapter, Slide ClampIV Catheter 14 Gauge x 3.25 Inch, Tubing with Stopcock 30 cm, (1) Pair Sterile Procedure Gloves, PVP Swabstick, Alcohol Prep Pad, Gauze Sterile Pad 4 X 4 Inch, Chest Drain Valve (Heimlich), Syringe 10 mLGauze 4 X 4 Inch Sterile 2’s 12 ply, Alcohol Prep Pad Sterile Medium 2ply, Luer Lock Syringe 10 mL, Tube with 3-Way Stopcock 30 cm, Angiocath 14 Gauge X 3.25 Inch, Angiocath 16 Gauge X 3.25 Inch, (1) Pair Triflex Surgical Glove Size 8, PVP Swab Sticks (1’s), Chest Valve (Heimlich)(1) Prep Tray, (1) CSR Wrap, (1) Absorbent Towel, 3 mL Applicator 2% ChloraPrep™ (1) wand, Fenestrated Drape, (6) 12-ply 3" x 3" Gauze sponges, (1) Procedure Tray 8 Fr. Turkel™ safety thoracentesis system, (1) 6 mL, 12 mL, 60 mL Moneject™ syringe, (1) 25 Ga. x 5/8" Magellan™ safety needle, (1) 21 Ga. x 1-1/2 Inch Magellan™ safety needle, (1) 20 Ga. x 1-1/2 Inch blunt tip filter aspiration needle, (1) #11 Retractable scalpel blade, (3) 8 mL Specimen vials, (1) Tip cap, (1) 1 X 3 Inch Curity™ adhesive bandage, (1) Drainage collection pouch: Automatic aspiration/purge valve and 36 Inch tubing set with set-up diagram, Standard 36 Inch tubing set and roller clamp with set-up diagram, 2000 mL drainage collection bag
Country of Origin MexicoUnknownTaiwanTaiwanUnknown
Drugs DrugsWithout DrugsWithout DrugsWithout Drugs
Procedure Needle Gauge 18 Gauge15 Gauge25 / 21 Gauge
Procedure Needle Length 7.5 X 18 Ga30 Inch5/8 Inch / 1-1/2 Inch
Procedure Needle Style Injection NeedleBottle NeedleSafety Needle
Type Pleura-SealSingle Use
Application Thoracentesis SetThoracentesis SetThoracentesis SetThoracentesis SetThoracentesis Set
UNSPSC Code 4214253742142537421425374214253742142537
Features and Benefits
  • One-Step Solution with Hi-Lite Orange™ Tint - Two: 5 ml Ampule HCl, 1% Lidocaine Solution - One: Vial: Specimen - One: Vial: Specimen - One: Vial: Specimen - One: SharpsAway II™
  • 2 Locking Disposal Cup - One: Drainage Bag - One: CSR Wrap - One: Drape: 18" x 24" with 2-3/4" fenestration, with adhesiv
  • One: Safety Scalpel: #11 - Two: Dressing: Adhesive 7.6 cm x 2.5 cm Five: Gauze Pad(s): 4" x 4" - One: Tubing Set: Drainage with Roller Clamp and 18 Ga. Needle (AK-01000-T)
  • One: FEP Centesis Device: 8 Fr. Catheter over 18 Ga. x 7-1/2" (19 cm) RW Needle with 3-way Stopcock, Self-Sealing Valve - One: Injection Needle: 22 Ga. x 1-1/2" (3.81 cm) - One: Injection Needle: 25 Ga. x 1" (2.54 cm) - One: Syringe: 10 mL Luer-Loc
  • One: Syringe: 5 mL Luer-Lock - One: Syringe: 60 mL Luer-Lock - One: Tubing Set with Aspiration/Discharge Device - One: 3 Swabstick Foil Pack 10% Povidone-Iodine - Two: 5 ml Ampule HCl, 1% Lidocaine Solution - One: Vial: Specimen - One: Vial: Specimen
  • One: Vial: Specimen One: Drainage Bag - One: CSR Wrap - One: Drape: 24" x 30" with 4" fenestration, with adhesive - One: Scalpel: #11 - Two: Dressing: Adhesive 7.6 cm x 2.5 cm - Five: Gauze Pad(s): 4" x 4" One: Tubing Set: Drainage with Roller Clamp and 18 Ga. Needle
  • Approximate priming volume is 4.25 mL
  • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Blunt safety cannula, housed within the sharp, beveled hollow needle protects underlying tissue from inadvertent penetration
  • Color coded indicator provides direct visualization of the safety cannula position as the needle is inserted
  • Ball valve in catheter housing; closed system prevents accidental pneumothorax
  • One-way duck bill valve in needle hub allows air and fluid to escape from the needle yet prevents atmospheric air from entering pleural space and prevents accidental pneumothorax
  • In-line stopcock provides convenient accessibility to drainage assembly while maintaining a closed system
  • WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov