Abbott Rapid Dx North America LLC 1115175
Abbott Rapid Dx North America LLC 1116985
Abbott Rapid Dx North America LLC 1116554
Abbott Rapid Dx North America LLC 13452
Abbott Rapid Dx North America LLC 1116970
McKesson # 839513 1139091 1101561 816208 1139600
Description Point-of-Care Analyzer Afinion 2 CLIA Waived (HbA1c) / CLIA Moderate Complexity Point-of-Care Analyzer Afinion™ 2 CLIA Waived Point-of-Care Analyzer Afinion™ 2 Point-of-Care Analyzer Cholestech LDX® CLIA Waived (Whole Blood) Point-of-Care Analyzer Afinion™ 2 CLIA Moderate Complexity
Manufacturer # 111517511169851116554134521116970
Brand Afinion 2Afinion™ 2Afinion™ 2Cholestech LDX®Afinion™ 2
Manufacturer Abbott Rapid Dx North America LLCAbbott Rapid Dx North America LLCAbbott Rapid Dx North America LLCAbbott Rapid Dx North America LLCAbbott Rapid Dx North America LLC
Invoice ANALYZER, HEMOGLOBIN AFINION AS1000 MULTI ASSYPOINT-OF CARE ANALYZER AFINION2 CLIA WAIVED D/SANALYZER 2, AFINION D/SANALYZER, LDX W/PRINTER CHOLSANALYZER, DX AFINION 2 PURCHASE ONLY D/S
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

CLIA Classification CLIA Waived (HbA1c) / CLIA Moderate ComplexityCLIA WaivedCLIA Waived (Whole Blood)CLIA Moderate Complexity
Contents1 1 Affinion 2 Analyzer, Quick Reference Guide, User Manual, Power GuideIncludes Analyzer, Printer, Power Supply, Optics Check Cassette, Printer Cable, User Manual, Starter Pack, Quick Reference Guide1 Afinion 2 Analyzer, Quick Reference Guide, User Manual, Power Cord
Country of Origin SwedenSwedenSwedenUnknownSweden
Dimensions 12-2/3 X 6-2/3 X 6-2/3 Inch7-1/5 X 7-1/2 X 13 Inch7-1/4 X 7-1/2 X 13 Inch8-1/4 X 4-3/4 Inch7-1/5 X 7-1/2 X 13 Inch
For Use With For Afinion™ Test Cassettes OnlyFor Afinion™ HbA1c and Afinion™ ACR Test Cassettes
Power Source AC / DC Power Adapter
Readout Type Print Out ResultsUSB Connection for Optional Barcode Reader and PrinterLCD Touch Display, Barcode Reader and Printer (Optional)Print OutUSB Connection for Optional Barcode Reader and Printer
Sample Application Type Test CassetteTest Cassette
Sample Type Whole Blood / Plasma / Urine SampleWhole Blood / Urine SampleWhole Blood / Urine SampleWhole Blood / Serum / Plasma SampleWhole Blood / Urine Sample
Test Name HbA1c, Albumin/Creatinine Ratio (ACR)HbA1c / Lipid Panel / ACR / CRPHbA1c, Albumin/Creatinine Ratio (ACR)Lipid Profile, Glucose, Total Cholesterol, HDL and LDL Cholesterol, TriglyceridesHbA1c / Lipid Panel / ACR / CRP
Time to Results 3 to 5 Minute Results5 Minute Results5 Minute Results
UNSPSC Code 4111581541115807411158074111620241115807
User Interface Color Touch DisplayColor TouchscreenLCD Touch DisplayColor Touchscreen
Weight 11 lbs.7.5 lbs7.5 lbs.7.5 lbs
Application Point-of-Care AnalyzerPoint-of-Care AnalyzerPoint-of-Care AnalyzerPoint-of-Care AnalyzerPoint-of-Care Analyzer
Features and Benefits
  • Multiparameter analyzer system
  • Designed to enable on-the-spot testing, using whole blood, plasma or urine samples
  • Integrated error detection system
  • Storage capacity: 500 patient results + 500 control results
  • Color touch display in local language
  • Test Cartridge with integrated Sampling Device
  • Bar coded label with test specific information
  • No end-user calibration of Analyzer or tests required
  • Power supply: AC/DC adapter
  • Interface: RS232 and USB port
  • Accessories: Barcode reader and printer
  • The Afinion™ 2 Analyzer is a compact, rapid, multi-assay analyzer that provides valuable near patient testing at the point-of-care
  • The analyzer is designed to enable simple and fast on-the-spot testing, regardless of the sample type, which may be whole blood, plasma or urine, and to deliver accurate results during patient consultation for improved patient management
  • The Afinion™ 2 Analyzer automatically transfers patient and control results via TCP/IP networking using the protocols POCT1-A, HL7, ASTM 1381-85 (low level) or ASTM 1394-97 (high level), selectable by configuration
  • The analyzer and test cartridges have been precision engineered with each test cartridge containing an integrated sample collection device and all necessary reagents for a single test
  • The Afinion™ 2 Analyzer eliminates erroneous results with integrated error detection and self-check systems
  • Four tests on one platform; HbA1c, Lipid Panel, ACR, CRP
  • Connectivity solutions that support POCT1-A
  • Extensive and comprehensive failsafe systems prevent the possibility of erroneous results
  • QC and operator lockout
  • The analyzer and test cartridges have been precision engineered with each test cartridge containing an integrated sample collection device and all necessary reagents for a single test
  • The Afinion™ 2 analyzer eliminates erroneous results with integrated error detection and self-check systems
  • Each Afinion™ 2 analyzer has a fixed factory calibration
  • The Afinion™ 2 analyzer can reliably transfer test information to a HIS or LIS system
  • The Afinion™ 2 Analyzer automatically transfers patient and control results via TCP/IP networking using the protocols POCT1-A, HL7, ASTM 1381-85 (low level) or ASTM 1394-97 (high level), selectable by configuration
  • Point of care testing for cholesterol and related lipids, blood glucose and liver enzymes serve as diagnostic tools that provide information for immediate risk assessment and therapeutic monitoring of heart disease, inflammatory disorders and diabetes
  • Lab-accurate quality: Meets National Cholesterol Education Program (NCEP) guidelines
  • Accurate and reproducible: Certified by the CDC’s LSP and CRMLN programs* (the lipid testing accuracy standards)
  • Rapid results: Immediate feedback enables on-the-spot CHD risk assessment and care decisions
  • Simple 3-step procedure and convenient fingerstick sample
  • CLIA-waived (for whole blood)
  • The Afinion™ 2 Analyzer is a compact, rapid, multi-assay analyzer that provides valuable near patient testing at the point-of-care
  • The analyzer is designed to enable simple and fast on-the-spot testing, regardless of the sample type, which may be whole blood, plasma or urine, and to deliver accurate results during patient consultation for improved patient management
  • The Afinion™ 2 Analyzer automatically transfers patient and control results via TCP/IP networking using the protocols POCT1-A, HL7, ASTM 1381-85 (low level) or ASTM 1394-97 (high level), selectable by configuration
  • The analyzer and test cartridges have been precision engineered with each test cartridge containing an integrated sample collection device and all necessary reagents for a single test
  • The Afinion™ 2 Analyzer eliminates erroneous results with integrated error detection and self-check systems
  • Four tests on one platform; HbA1c, Lipid Panel, ACR, CRP
  • Connectivity solutions that support POCT1-A
  • Extensive and comprehensive failsafe systems prevent the possibility of erroneous results
  • QC and operator lockout