Product Comparison


 
Quidel 97022BD
BD 446252
Quidel 98000XR
Quidel 97022HS
BD 245240
McKesson # 824760 365609 575746 824761 913936
Description Test Kit Triage® Combo 4 Cardiac Marker / Immunoassay B-Type Natriuretic Peptide (BNP) / Creatine Kinase MB / D-Dimer / Troponin I Whole Blood / Plasma Sample 3 X 25 Tests CLIA Moderate Complexity Test Kit Affirm™ VPIII Microbial Identification Candida Species / Gardnerella Vaginalis / Trichomonas Vaginalis Vaginal Secretion Sample 24 Tests Non Waived Test Kit Triage® Cardiac Marker / Immunoassay B-Type Natriuretic Peptide (BNP) Whole Blood / Plasma Sample 25 Tests CLIA Waived for Whole Blood / CLIA Moderate Complexity for Plasma Test Kit Triage® Cardiac Marker / Immunoassay Creatine Kinase MB / Troponin I Whole Blood / Plasma Sample 25 Tests CLIA Moderate Complexity Test Kit BBL™ Crystal™ Microbial Identification Gram-Positive Identification Isolated Colonies / Culture Sample 20 Tests CLIA High Complexity
Manufacturer # 97022BD44625298000XR97022HS245240
Brand Triage® Combo 4Affirm™ VPIIITriage®Triage®BBL™ Crystal™
Manufacturer QuidelBDQuidelQuidelBD
Invoice TEST KIT, TROPONIN CKMB W/BNP D-DIMER 3X25 (25/CT BIOSTETEST KIT, AFFIRM VPIII (24/KT)TEST KIT, BNP TRIAGE B-TYPE NARIURETICPEPTD25TSTTEST KIT, TROPONIN W/CKMB 2X25(25/CT)CRYSTAL GRAM/POSITIVE ID KIT
    Log In to Order   Log In to Order   Log In to Order   Log In to Order   Log In to Order

Comparison

CLIA Classification CLIA Moderate ComplexityNon WaivedCLIA Waived for Whole Blood / CLIA Moderate Complexity for PlasmaCLIA Moderate ComplexityCLIA High Complexity
Contents 1 (25) BNP Test Devices, (25) Cardiac Test Devices, (25) D-Dimer Test Devices, Reagent Code Chip Module, Printer Paper Roll, (25) Pipettes, Package Insert(24) Probe Analysis Cards, (24) Reagent Cassettes, 3.4 mL Substrate Solution, 10.8 mL Lysis Solution, 15 mL Buffer Solution, (24) Filter Tips, (24) Sample Collection Cups, (24) Sample Collection Tubes, (24) Sterile Swabs(25) Test Devices, Reagent Code Chip Module, Printer Paper Roll, (25) Pipettes, Package Insert(25) Test Devices, (25) Transfer Pipettes, Reagent Code Chip Module, Printer Paper Roll(20) BD BBL Crystal GP ID Panel Lids, (20) BD BBL Crystal Bases, (20) BD BBL Crystal GP Inoculation Fluid Tubes, (2) Incubation Trays, Report Pad
Country of Origin United StatesUnknownUnited StatesUnited StatesUnknown
For Use With For Triage® MeterPro® SystemFor Triage® MeterPro® SystemFor Triage® MeterPro® SystemFor BD BBL Crystal AutoReader
Number of Tests 3 X 25 Tests24 Tests25 Tests25 Tests20 Tests
Product Dating McKesson Acceptable Dating: we will ship >= 60 daysMcKesson Acceptable Dating: we will ship >= 60 daysMcKesson Acceptable Dating: we will ship >= 90 daysMcKesson Acceptable Dating: we will ship >= 60 days
Reading Type Machine ReadVisual ReadMachine ReadMachine ReadMachine Read / Visual Read
Sample Type Whole Blood / Plasma SampleVaginal Secretion SampleWhole Blood / Plasma SampleWhole Blood / Plasma SampleIsolated Colonies / Culture Sample
Test Format Cassette FormatTest Card FormatCassette FormatCassette FormatMicrowell Format
Test Method Fluorescence Immunoassay (FIA)Fluorescence Immunoassay (FIA)Fluorescence Immunoassay (FIA)
Test Name B-Type Natriuretic Peptide (BNP) / Creatine Kinase MB / D-Dimer / Troponin ICandida Species / Gardnerella Vaginalis / Trichomonas VaginalisB-Type Natriuretic Peptide (BNP)Creatine Kinase MB / Troponin IGram-Positive Identification
Test Type Cardiac Marker / ImmunoassayMicrobial IdentificationCardiac Marker / ImmunoassayCardiac Marker / ImmunoassayMicrobial Identification
Time to Results 20 Minute Results45 Minute Results20 Minute Results20 Minute Results
UNSPSC Code 4111610441116129411161044111610441116129
Application Test KitTest KitTest KitTest KitTest Kit
Storage Requirements Requires RefrigerationRequires RefrigerationRequires RefrigerationRequires RefrigerationRequires Refrigeration
Features and Benefits
  • Tnl / CKMB, BNP and D-Dimer on three test devices
  • The Affirm™ VPIII Microbial Identification Test is a DNA probe test intended for use in the detection and identification of Candida species, Gardnerella vaginalis and Trichomonas vaginalis nucleic acid in vaginal fluid specimens
  • The test uses two distinct single-stranded nucleic acid probes for each organism, a capture probe and a color development probe, that are complementary to unique genetic sequences of the target organisms
  • The capture probes are immobilized on a bead embedded in a Probe Analysis Card (PAC), which contains a separate bead for each target organism
  • The color development probes are contained in a multi-well Reagent Cassette (RC)
  • Kit includes: 24 Probe Analysis Cards (PAC), 24 Reagent Cassettes (RC), 3.4 mL Substrate Solution, 10.8 mL Lysis Solution, 15 mL Buffer Solution, 24 Filter Tips, 24 Sample Collection Cups, 24 Sample Collection Tubes, 24 Sterile Swabs
  • Individually packaged cards, wrapped in an absorbent paper towel moistened with a solution containing sodium azide (0.1%, w/v) as a preservative
  • Each PAC contains the following five beads: Negative Control, Trichomonas, Gardnerella, Candida, and Positive Control
  • Reagents are sealed in multi-well, foil covered cassettes
  • Each cassette has seven wells
  • All reagents are supplied ready for use
  • The Triage BNP test measures BNP to aid in the diagnosis and assess the severity of congestive heart failure
  • The test is also used for the risk stratification of patients with acute coronary syndromes and patients with heart failure
  • Sensitivity 80.6%, specificity 98%
  • Rapid results in approximately 15 minutes
  • Results read by the Triage meterpro meter
  • Sample Type: whole blood, plasma
  • CLIA Waived for Whole Blood
  • Tnl / CKMB on one test device
  • The BD BBL™ Crystal™ identification system is a miniaturized identification system that requires only one step for inoculation
  • The BD BBL Crystal GP ID panels contain 29 dried biochemical and enzymatic substrates
  • A bacterial suspension in the inoculum fluid is used for rehydration of the substrates
  • Once inoculated, the panels provide a safe and easy-to-handle closed system
  • Lids are individually packaged and must be stored unopened in a refrigerator
  • Bases are packaged in two sets of ten, in BD BBL Crystal incubation trays
  • BD BBL Crystal Inoculum Fluid (IF) is packaged in two sets of ten tubes
  • The Crystal panels may be read manually or with the BBL Crystal AutoReader