Comparison |
Application |
Coagulation Analyzer | Coagulation Analyzer | Coagulation Analyzer | Point-of-Care Coagulation Analyzer | Coagulation Analyzer |
CLIA Classification |
CLIA Waived | CLIA Moderate / High Complexity | | | CLIA Moderate / High Complexity |
Contents 1 |
(1) PT2 Pro Meter, Pro User's Manual, Pro Quick Reference Guide, Auto Single Use 21 Gauge Lancets - Starter Bag (8), AC Wall Adapter, (54) Sample Transfer Tubes With Plungers and Carrying Case; 1-year warranty | | | | |
Country of Origin |
United States | United States | Japan | Unknown | Poland |
Dimensions |
1-1/5 X 4 X 6 Inch | 19.5 X 19.5 X 22.5 Inch | 19.5 X 19.5 X 22.5 Inch | 40 X 70 X 170 mm | 19.5 X 19.5 X 22.5 Inch |
For Use With |
| | | For PT/INR Test Strips | |
Power Source |
Battery Operated | | 100 to 240 VAC, 50/60 Hz | Battery | |
Readout Type |
LCD Touch Screen Display | | Thermal Printer | Digital Readout | |
Sample Capacity |
10 μL | | 10 Sample Tubes | 6 µL | |
Sample Type |
Whole Blood Sample | Whole Blood Sample | Blood Sample | Fresh Capillary Whole Blood Sample | Whole Blood Sample |
Test Name |
Prothrombin Time Test (PT/INR) | Clotting Detection Only | PT, APTT, Fibrinogen, Thrombin Time, Batroxobin Time, Factor Deficiency, Lupus Anticoagulant, Protein C Pathway, Heparin, Antithrombin, D-Dimer, Von Wilebrand Factor | PT, INR | Clotting Detection Only |
Throughput |
| Up to 60 Tests per Hour | 60 Tests per Hour (PT) / 16 Tests per Hour (D-Dimer) / 48 Tests per Hour (PT, APTT, Fibrinogen) / 40 Tests per Hour (PT/APTT/Fibrinogen/AT) / 32 Tests per Hour (PT/APTT/Fib/D-Dimer) | | Up to 60 Tests / Hour |
Time to Results |
< 1 Minute Results (Patients Acutal Clotting Time) | | | | |
UNSPSC Code |
41115810 | 41115809 | 41115809 | 41115828 | 41115809 |
User Interface |
Color Touchscreen | Color Touch Screen Display | Touch Screen, Barcode Reader | Touch Screen, Barcode Reader | Color Touch Screen Display |
Weight |
| 94.6 lbs. | 94.6 lbs. | 300 Gram | 94.6 lbs. |
Features and Benefits |
- PT2 fits in a pocket
- Color touch screen display – easy to follow instructions in plain language
- Wi-Fi, Bluetooth, Ethernet, USB
- Near Field Communication (NFC) – replaces bar code reader to communicate test strip lot information
- Rechargeable Lithium Polymer battery – micro USB charging
- Expanded Memory- 2,000 patient test results and 500 QC results
|
- The Sysmex CA-620 System offers clotting testing methodology for laboratories that primarily perform routine tests
- Ideal for low-volume laboratories or as a backup instrument for large laboratories
- The Siemens commitment to standardized reagents, quality control, and consumables reduces waste and saves time through streamlined ordering and maintenance
- Hand-held two-dimensional barcode reader simplifies the data entry process for ISI, control and calibrator values, lot numbers, and expiry information
- Tilted color LCD touch screen for easy-to-use system handling
- Sample bar-code reader provides simplified sample ID processing and enables security and integrity of patient records
|
- Hand-held 2-D bar-code reader automates the data entry process for calibrator and control values
- Easy-to-use system handling with intuitive menu structure and tilted color touch-screen
- STAT sample processing enables critical tests to be processed at any time
- Analyzed data may be displayed or printed with reaction curves for flexibility in result management
- Environmentally friendly system with minimized reaction tube waste
- Menu includes the most frequently requested routine and specialty tests, including INNOVANCE® D-Dimer*
- Method/channels: Clotting/4, chromogenic, and immunologic
- Continuous random access (reaction tubes)
- Automatic predefined calibration
|
- Touchscreen features include bright-color interface with step-by-step instructions help guide the user
- Lot calibration using integrated bar-code reader
- Test strip eject button reduces potential biohazard exposure
- Operator lockout feature restricts analyzer use to trained staff only
- Design is compact and portable to enable fast, efficient patient testing at the point of care
- Test requires only small sample applied at tip of strip
- Lab confirmatory testing may be reduced because of good correlation to lab results
- Barcode scanner offers patient and operator ID entry
- Reporting range: 0.8 to 4.5 INR. Results outside this range will be displayed as out of range
- At minimum, 640 patient results, 300 liquid quality control results, 300 error messages
- 36 Months warranty
|
- The Sysmex CA-620 System offers clotting testing methodology for laboratories that primarily perform routine tests
- Ideal for low-volume laboratories or as a backup instrument for large laboratories
- The Siemens commitment to standardized reagents, quality control, and consumables reduces waste and saves time through streamlined ordering and maintenance
- Hand-held two-dimensional barcode reader simplifies the data entry process for ISI, control and calibrator values, lot numbers, and expiry information
- Tilted color LCD touch screen for easy-to-use system handling
- Sample bar-code reader provides simplified sample ID processing and enables security and integrity of patient records
|