Product Comparison


 
BD Primary Care 256066
Siemens 10282969
BD Primary Care 256068
McKesson # 1029527 641021 1029528
Description Point-of-Care Immunoassay Analyzer BD Veritor™ Plus CLIA Waived Point-of-Care Immunoassay Analyzer DCA Vantage® 3 Tests CLIA Waived (HbA1c) Point-of-Care Immunoassay Analyzer InfoScan Moduleritor CLIA Waived
Manufacturer # 25606610282969256068
Brand BD Veritor™ PlusDCA Vantage®InfoScan Moduleritor
Manufacturer BD Primary CareSiemensBD Primary Care
Invoice READER, BD VERITOR PLUS ANALYZER DSANALYZER, HBA1C DCA VANTAGE D/SVERITOR, INFOSCAN MODULE ADD INFOSCAN MODULE ADD ON D/S
    Log In to Order   Log In to Order   Log In to Order

Comparison

CLIA Classification CLIA WaivedCLIA Waived (HbA1c)CLIA Waived
Contents1 BD Veritor Plus Analyzer, Instructions for Use Manual, USB Port Unlock Barcode Label, AC Power Adapter, BD Verification CartridgeModule Only
Country of Origin ChinaUnited KingdomChina
Dimensions 7.6 X 9 X 14.3 cm9 X 10 X 11-1/2 Inch7.6 X 9 X 14.3 cm
For Use With For BD Veritor™ System Test DevicesFor Immunoassay CartridgeFor BD Veritor™ System Test Devices
Number of Tests 3 Tests
Power Source 100 to 240 VAC at 50 to 60 Hz, 0.6A100 to 240 VAC, 50/60 Hz, 70 VA, 30 Watts100 to 240 VAC at 50 to 60 Hz, 0.6A
Readout Type Digital Readout, Printout (Option)Digital Display / PrinterDigital Readout, Printout (Option)
Sample Type Throat Swab / Nasal Swab / Nasopharyngeal Swab / Nasopharyngeal Aspirate or Wash SampleWhole Blood / Urine SampleThroat Swab / Nasal Swab / Nasopharyngeal Swab / Nasopharyngeal Aspirate or Wash Sample
Test Name Influenza A + B, Respiratory Syncytial Virus (RSV), and Group A StrepHemoglobin A1c, Albumin, Microalbumin/Creatinine, Creatinine, Albumin-to-Creatinine (A:C) RatioInfluenza A + B, Respiratory Syncytial Virus (RSV), and Group A Strep
Time to Results 5 to 10 Minute Results6 Minute HbA1c Results / 7 Minute A:C Ratio Results5 to 10 Minute Results
UNSPSC Code 411161444111581941116144
User Interface LCD DisplayColor Touch Screen Display / Bar Code ReaderLCD Display
Weight 300 g9 lbs.350 g
Application Point-of-Care Immunoassay AnalyzerPoint-of-Care Immunoassay AnalyzerPoint-of-Care Immunoassay Analyzer
Features and Benefits
  • CLIA-waived digital immunoassay for rapid detection of Flu A+B, RSV and Group A Strep
  • Advanced particle technology enhances sensitivity by using a proprietary process to produce highly stable, modifi ed colloidal metal particles, helping improve test performance
  • Adaptive read technology helps improve specificity to reduce false-positive results by compensating for background and non-specific binding
  • Fast and accurate assay performance— after 10 minute incubation for Flu A+B and RSV; after 5 minute incubation for Group A Strep
  • Prefilled color-coded unitized tubes by reagent facilitate workflow
  • Swab or liquid sample is inserted into unitized tube, processed and removed
  • Test device may be inserted immediately into Analyzer (Walk Away mode) or after incubation time is complete (Analyze Now mode)
  • Print-enabled through USB
  • The DCA Vantage Analyzer is the diabetes system that delivers clinically proven, clinically relevant HbA1c and A:C Ratio results shown to improve patient compliance
  • Only 1uL of whole blood needed for HbA1c testing
  • HbA1c results in 6 minutes
  • Microalbumin testing allows for early detection of kidney disease – results available in 7 minutes
  • Printed patient records and electronic transmission to LIS or electronic medical record allows for reduced transcription errors
  • Lot-specific calibration card provides automatic calibration with every cartridge
  • Storage Capacity/Memory: 4000 patient and/or control records and up to 1,000 operator IDs
  • Onboard Printer: 54 mm (2 in) width, thermal/label stock
  • CLIA Waived Hgb A1c
  • CLIA Moderate Complexity for Microalbumin and Creatinine
  • CLIA-waived digital immunoassay for rapid detection of Flu A+B, RSV and Group A Strep
  • Advanced particle technology enhances sensitivity by using a proprietary process to produce highly stable, modifi ed colloidal metal particles, helping improve test performance
  • Adaptive read technology helps improve specificity to reduce false-positive results by compensating for background and non-specific binding
  • Fast and accurate assay performance— after 10 minute incubation for Flu A+B and RSV; after 5 minute incubation for Group A Strep
  • Prefilled color-coded unitized tubes by reagent facilitate workflow
  • Swab or liquid sample is inserted into unitized tube, processed and removed
  • Test device may be inserted immediately into Analyzer (Walk Away mode) or after incubation time is complete (Analyze Now mode)
  • Print-enabled through USB
  • BD Veritor™ InfoScan module facilitates traceability
  • Reduces hands-on time through automated documentation
  • Documentation functionality including operator ID, specimen ID, and test kit lot to enhance quality control
  • Local data storage and download options for improved traceability
  • BD Veritor is not included